文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

2 项

设置提升方向
HSA检测
SENSORS AND ACTUATORS B-CHEMICAL · 2024 · IF 8

Temperature-insensitive cascaded micro-ring resonator silicon photoelectric sensor based on wavelength interrogation for HSA detection

Zhaoyu Wang,Mingyu Li,Xin Chen,Kaihao Zhao,Jiamei Gu,Jian-Jun He,Qiu-Shun Li,Wen-Fei Dong

Silicon-based optical biosensors have garnered significant interest since their inception. They are, however, susceptible to temperature fluctuations in a controlled environment. In order to address this issue, we provide a solution including the utilization of a silicon-on-insulator (SOI) cascaded micro-ring resonators (CMRR) biosensor that is designed to be insensitive to temperature changes. It consists of two ring resonators exposed to the reference solution and analyte, respectively, their radius and waveguide width are designed to meet the temperature - insensitivity criterion of the CMRR sensor. The results of experiments indicate that by real-time monitoring of the envelope peak drift in the transmission spectrum of the sensor, the bulk refractive index (RI) sensitivity is 2940.71 nm/RIU, the limit of detection (LOD) is 3.1×10 −5 RIU, and the temperature sensitivity is less than 40 pm/℃. Furthermore, the sensor was applied for HSA detection, with a calculated LOD of 18.09 ng/mL. The effect of temperature on HSA detection is much smaller than that of a CMRR sensor without athermal design. The sensor demonstrates high sensitivity and temperature insensitivity, and the absence of negative thermo-optic coefficient materials or supplementary temperature control mechanisms simplifies its practical applications. It can be made by a large array to detect different type protein molecules for high throughput multiparameter analysis.

CAS / MDL: 9048-46-8 4432-31-9
研究领域: 生物医学工程 · 光学传感 · 分子检测
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
DYES AND PIGMENTS · 2024 · IF 4.1

A supramolecular ratiometric fluorescent probe for the detection of human serum albumin

Xue Liu,Shuang Qi,Jingyao Mao,Yuteng Zhang,Bin Dong,Bo Song,Lingling Ji

In this study, an amphiphilic organic fluorescent molecule (denoted by BCPB) was employed as a ratiometric fluorescent probe for the detection of human serum albumin (HSA). In an aqueous solution, the micellar assemblies of BCPB showed a strong excimer emission at 660 nm. The presence of HSA can induce the disassembly of BCPB aggregates and reassemble with HSA to form BCPB-HSA complexes, resulting in a ratio change in the fluorescence emission of BCPB at 540 nm (monomer) and 660 nm (aggregate). Accordingly, the fluorescence color also undergoes a visually recognizable change from red to green. As a ratiometric fluorescence probe of HSA, BCPB has a fast response (<5 s), low limit of detection (8.3 nmol L −1 , S / N  = 3), good selectivity, and strong anti-interference ability. Finally, BCPB was loaded into the hydrogel to prepare a portable hydrogel kit, which successfully realized the in situ visual detection of HSA in an aqueous solution and human serum.

研究领域: 分析化学 · 生物化学 · 材料科学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。