文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
HSV分析
TALANTA · 2025 · IF 6.1

A Mn–O–Ce interface-engineered nanozyme platform for visual stratified exosome screening of lung cancer: Toward primary care application

Xin Xu,Ting Ying,Zhanghuan Yang,Ze Zhang,Liang Hu,Tong Shen,Dejian Li,Rui Zhu,Dong Chang

The development of portable exosome detection platforms is crucial for noninvasive early diagnosis of lung cancer, particularly in resource-limited settings. Herein, we engineered a paper-based colorimetric biosensor utilizing a MnO 2 /CeO 2 heterojunction nanozyme for visual quantification of plasma exosomes. The heterojunction synergistically integrates the high surface area of CeO 2 (45.689 m 2 /g) with the nanorod shaped MnO 2 , generating an interfacial electron transfer pathway that enhances peroxidase-like activity by 1.77 and 5.87 fold (K m  = 1.197 mM, V max  = 0.884 M/min) compared to individual components. Molecular recognition was achieved through dual-target immobilization: exosome-specific aptamers and anti-CD63/FGG/FGB antibodies conjugated on a chitosan-modified cellulose substrate. A smartphone-based hue-saturation-value (HSV) analysis system embedded in the platform enabled rapid on-site screening within 15 min, followed by microplate scanning of suspected high-risk samples, achieving a detection range of 10 2 –10 8 particles/μL with an ultralow detection limit of ∼2 particles/μL. Integration of a logistic regression model incorporating CD63, FGG, and FGB absorbance values further improved classification robustness. Clinical validation using 194 plasma samples demonstrated exceptional diagnostic accuracy in discriminating malignant from benign pulmonary nodules (AUC = 0.996), with a 95 % confidence interval ranging from 0.797 to 1.05, with 98.51 % sensitivity and 95.52 % specificity. This work establishes a multimodal strategy combining heterojunction nanozyme catalysis, paper-based microfluidics, smartphone-assisted imaging, and machine learning, offering a scalable paradigm for liquid biopsy applications in primary healthcare.

研究领域: 生物传感器 · 纳米技术 · 癌症诊断 · 即时检测 · 微流控技术 · 机器学习 · 生物医学工程
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。