Ferrous ion (Fe2+) is an important component of hemoglobin and plays a role in transporting O2 to human tissues. If iron deficiency is present, iron deficiency anemia may occur, so it is critical to develop sensitive and accurate methods to detect Fe2+. Herein, a novel luminescence energy transfer (ET) system has been designed for the sensitive detection of Fe2+ by a single-particle enumeration (SPE) method in the near-infrared (NIR) region through combining NIR-to-NIR β-NaGdF4:Yb,Tm@NaYF4 upconversion nanoparticles (UCNPs) and IR-808 dye. IR-808 dye can quench the luminescence of the UCNPs because of the efficient overlap between the absorption spectrum of IR-808 and the emission spectrum of the UCNPs. When Fe2+ and H2O2 are added to the system, the Fenton reaction produces hydroxyl radicals (˙OH). The generated ˙OH reacts with IR-808 and the structure of IR-808 is destroyed. As a result, the ET process is suppressed, causing recovery of the luminescence of the UCNPs, which is reflected as an increase in the number of luminescent particles. Accurate quantification of Fe2+ is achieved by statistically counting the target concentration-dependent luminescent particles. Under the optimal conditions, the linear detection range of Fe2+ is 5–10 000 nM, which is much wider than the ensemble luminescence spectra measurements in bulk solution. Moreover, this strategy can be applied to detection in serum samples with satisfactory results.
Zheng Liu,Feng Ren,Hao Zhang,Qiang Yuan,Zhilin Jiang,Hanghang Liu,Qiao Sun,Zhen Li
Rare-earth nanoparticles (RE NPs) with narrow long wavelength emissions have been recently investigated for their potential application for fluorescence imaging in the second near-infrared window (NIR-II). Previously these RE NPs have a very limited application in the diagnosis and treatment of deep-seated tumors such as brain tumors, due to their weak fluorescence in the range of 1300–1700 nm. Herein, we report a significant enhancement of more than 10 times regular emission of NaNdF 4 nanoparticles at 1340 nm wavelength by coating them with an inert layer of NaLuF 4 , followed by sensitizing with a near-infrared dye (IR-808). We deliver these highly bright nanoparticles into the brain by using focused ultrasound to temporarily open the blood-brain barrier (BBB), and then detect the orthotopic glioblastoma by fluorescence imaging at 1340 nm. The images obtained from long wavelength fluorescence ( i.e. 1340 nm) exhibited better resolution and contrast compared to the short wavelength fluorescence ( i.e. 1060 nm). Our study not only provides insights for enhancing often overlooked emissions of rare-earth nanoparticles for NIR-II fluorescence imaging of deep-seated tumors, but also demonstrates great potential of focused ultrasound based technology in delivering nanotheranostic agents.