文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

3 项

设置提升方向
KClO4
VACUUM · 2020 · IF 2.906

Insight into the thermal decomposition properties of potassium perchlorate (KClO4)-based molecular perovskite

Qi Jia,Peng Deng,Xiaoxia Li,Lishuang Hu,Xiong Cao

Studying thermal decomposition properties of the perchlorate-based molecular perovskite energetic materials is essential to facilitate the potential applications. In this work, thermal decomposition properties of potassium perchlorate (KClO4)-based molecular perovskite were investigated. Potassium perchlorate -based molecular perovskite (H 2 dabco)[K(ClO 4 ) 3 ] were prepared by the one-pot reaction of KClO 4 , HClO 4 and triethylenediamine (dabco). The samples were characterized. The results show that (H 2 dabco)[K(ClO 4 ) 3 ] has ternary organic-inorganic perovskite crystal structures. The thermal decomposition results demonstrated that molecular perovskite (H 2 dabco)[K(ClO 4 ) 3 ] has a lower decomposition temperature (383.6 °C) and a higher heat release (2815 J g −1 ) than 607.7 °C and 313 J g −1 of the monocomponent KClO 4 , respectively. The activation energy of thermal decomposition of (H 2 dabco)[K(ClO 4 ) 3 ] had been reduced appreciably from 191.2 kJ mol −1 to 177.7 kJ mol −1 . A synergistic catalysis thermal decomposition mechanism based on unique molecular perovskite structure was proposed. This work offers a novel understanding for thermal decomposition of the molecular perovskite energetic materials.

CAS / MDL: 280-57-9
研究领域: 材料科学 · 化学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
Scientific Reports · 2017 ·Vol. 7 ·期 1 ·1-9 · IF 4.259

Preparation of core-shell structure KClO4@Al/CuO Nanoenergetic material and enhancement of thermal behavior

Yang Fan,Kang Xiaoli,Luo Jiangshan,Yi Zao,Tang Yongjian

In this paper, a solvent/non-solvent synthetic approach has been utilized in preparing a new nanoenergetic material KClO 4 @Al/CuO by coating Al/CuO nanocomposites particles with a layer of nanoscale oxidizer KClO 4 . The coating process and mechanism are discussed. The composites of Al/CuO are uniformly mixed by mechanical ball milling process and CuO acts as a catalytic metallic oxide. The ternary mixtures KClO 4 @Al/CuO were characterized by X-ray diffraction (XRD) and the results reveal that after ball-milling and chemical synthesis process, the phase compositions haven’t changed. Scan electron microscopy (SEM) images show that these energetic nanocomposites consist of small clusters of Al/CuO that are in intimate contact with a continuous and clear-cut KClO 4 layer (100–400 nm). In a Scanning transmission electron microscopy (STEM) elemental map, high K/Cl intensity on the perimeter of the nanoparticles and high Cu/Al content in the interior powerfully demonstrated the KClO 4 @Al/CuO core-shell nanostructure. Electrical ignition experiments and pressure cell test prove that these nanoenergetic composites are more sensitive to ignition with much higher burning rate than traditional formulations (conventional counterparts). To quantify the enhancement of thermal behavior, Thermogravimetry (TG) and Differential scanning calorimetry (DSC) were performed and the results show that the burning rate of these energetic nanocomposites nearly tripled.

研究领域: 材料科学 · 含能材料 · 纳米技术 · 热分析
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
OPTICS EXPRESS · 2017 ·Vol. 25 ·期 20 ·A932 · IF 3.307

Laser emission from flash ignition of Zr/Al nanoparticles

Fan Yang,Xiaoli Kang,Jiangshan Luo,Laixi Sun,Handing Xia,Zao Yi,Yongjian Tang

We report the first laser emission from flash ignition of Zr/Al nanoparticles with the addition of strong oxidizer KClO4 using Nd: YAG as a laser medium. The mixture Zr/Al/Kp-45 (mass ratio = 33%Zr: 33%Al: 34%KClO4) has the highest brightness temperature Tb = 4615 K and the adiabatic flame temperature Tf = 4194 K with the duration of 20 ms. At 1064 nm we measured a maximum output energy of 702.5 mJ with the duration of nearly 10 ms by using only 100 mg mixture with an output coupler (transmission T = 10%). Further optimizing the concentration cavity and increasing the mixture content will yield much higher efficiency and output energy.

CAS / MDL: 7429-90-5
研究领域: 材料科学 · 光学 · 激光物理
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。