文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

2 项

设置提升方向
Lp-PLA2
ACS Sensors · 2023 · IF 8.9

Novel Electrochemiluminescent Immunosensor Using Dual Amplified Signals from a CoFe Prussian Blue Analogue and Au Nanoparticle for the Detection of Lp-PLA2

Lixin Wang,Yuhong Liu,Jilin Yan,Huiling Li,Yifeng Tu

Coronary heart disease (CHD) poses an important threat to human health, and its pathogenesis is the formation of atheromatous plaques in coronary ventricles. Compared to other biomarkers, lipoprotein-associated phospholipase A2 (Lp-PLA2), which is involved in multiple processes of atherosclerosis, is a noticeable inflammatory biomarker related to CHD. Herein, using a multifunctional nanocomposite containing a CoFe Prussian blue analogue (PBA) and Au nanoparticles (AuNPs) (AuNPs@CoFe PBA) as a sensing substrate, an electrochemiluminescent (ECL) immunosensor was developed for the highly sensitive detection of Lp-PLA2. Benefiting from the synergistic effect of the PBA and AuNPs, the nanocomposite exhibits excellent peroxidase-like activity and can catalyze the luminol–ECL reaction, amplifying the ECL signal by ∼29-fold. Meanwhile, the enlarged specific surface area of the nanocomposite and the presence of abundant AuNPs allow the immobilization of more antibody proteins, thereby improving the sensing response of the immunosensor. When the target Lp-PLA2 is captured by the antibody on the sensor surface, the sensor emits a reduced ECL signal because of the increased mass and electron transfer resistance due to the formation of the immune complex. Under optimized conditions, the constructed ECL immunosensor exhibits a broad linear range from 1 to 2200 ng/mL and a low detection limit of 0.21 ng/mL. Additionally, the ECL immunosensor exhibits high specificity, stability, and reproducibility. This work provides a new approach to diagnose CHD and broadened the application of the PBA in the field of ECL sensors.

研究领域: 医学诊断 · 生物传感 · 纳米技术
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
ANALYTICAL AND BIOANALYTICAL CHEMISTRY · 2020 ·Vol. 413 ·期 1 ·235-244 · IF 3.637

Au-coated Fe3O4 core-shell nanohybrids with photothermal activity for point-of-care immunoassay for lipoprotein-associated phospholipase A2 on a digital near-infrared thermometer

Guo Haixin,Su Xiaoping,Su Qingfu,Zhuang Wei,You Zhijiao

A portable photothermal immunoassay based on Au-coated magnetic Fe 3 O 4 core-shell nanohybrids (Au-Fe 3 O 4 ) was developed for point-of-care (POC) testing of lipoprotein-associated phospholipase A 2 (Lp-PLA 2 ) on a digital near-infrared (NIR) thermometer. Au-Fe 3 O 4 photothermal materials were first synthesized through reverse micelle method, and then functionalized with polyclonal rabbit anti-human Lp-PLA 2 antibody. A sandwiched immunoreaction was carried out in polyclonal mouse anti-human Lp-PLA 2 antibody-coated microplate using Au-Fe 3 O 4 -labeled antibody as the detection antibody. With formation of sandwich-type immunocomplex, the captured Au-Fe 3 O 4 on the plate converted the light into heat under an 808-nm laser irradiation (1.5 W cm −2 ), thereby resulting in the increasing temperature of the detection solution. The temperature variations relative to surrounding temperature was determined on a portable NIR thermometer. Several labeling protocols with gold nanoparticle, Fe 3 O 4 nanoparticle, or Au-Fe 3 O 4 nanohybrids were investigated for determination of Lp-PLA 2 and improved analytical features were achieved with the core-shell Au-Fe 3 O 4 nanohybrids. Under optimum conditions, Au-Fe 3 O 4 -based immunoassay exhibited good photothermal responses for the detection of Lp-PLA 2 with a dynamic linear range of 0.01–100 ng mL −1 at a low detection limit of 8.6 pg mL −1 . Good reproducibility and intermediate precision were less than 9.7%. Other biomarkers or proteins did not interfere with responses of this system. An acceptable accuracy was acquired for analysis of human serum sample between Au-Fe 3 O 4 -based photothermal immunoassay and commercialized human Lp-PLA 2 ELISA kit.

研究领域: 纳米技术 · 生物医学工程 · 分析化学 · 即时检测 · 免疫学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。