文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
MMP抑制剂
BIOSENSORS & BIOELECTRONICS · 2021 · IF 10.618

Electrochemically induced grafting of ferrocenyl polymers for ultrasensitive cleavage-based interrogation of matrix metalloproteinase activity

Qiong Hu,Luofeng Su,Yan Mao,Shiyu Gan,Yu Bao,Dongdong Qin,Wei Wang,Yuwei Zhang,Li Niu

Being closely associated with a variety of physiological and pathological processes, matrix metalloproteinases (MMPs) are useful as potential targets for drug therapy and informative markers for disease diagnosis. On the basis of the electrochemically induced grafting of ferrocenyl polymers and the proteolytic cleavage of recognition peptide, a novel electrochemical sensor is presented in this work for the highly specific interrogation of MMP activities at ultralow levels. The recognition peptide, to be immobilized via the N-terminus, is free of carboxyl group. The presence of the target MMP would cleave the end-tethered recognition peptide, generating a free carboxyl group at the C-terminus of the rest fragment. To be used as the reversible addition−fragmentation chain-transfer (RAFT) agent, the dithiobenzoate, 4-cyano-4-(phenylcarbonothioylthio)pentanoic acid (CPAD), can therefore be tethered via the carboxylate-Zr(IV)-carboxylate chemistry. Subsequently, the grafting of ferrocenyl polymers through electrochemically induced RAFT (eRAFT) polymerization of ferrocenylmethyl methacrylate (FcMMA) would recruit a large quantity of Fc redox reporters on electrode surface . With benefits from the excellent specificity of the enzyme-substrate recognition, the presented cleavage-based sensor is highly selective. Under optimal conditions, the detection limit in the presence of MMP-2 as the model target can be as low as 0.27 pg mL −1 , with a linear range from 1 pg mL −1 to 1 ng mL −1 . Furthermore, its applicability in the interrogation of MMP activity in complex serum samples and the screening of MMP inhibitors is satisfactory. The presented cleavage-based electrochemical MMP sensor is easy to fabricate and low-cost, thus showing great promise in drug discovery and disease diagnosis.

CAS / MDL: 7791-03-9
研究领域: 生物化学 · 分析化学 · 生物传感器 · 药学 · 诊断学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。