文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
MQSCl
RAPID COMMUNICATIONS IN MASS SPECTROMETRY · 2022 ·Vol. 36 ·期 17 ·e9345 · IF 2.586

Determination of estrogens in human serum using a novel chemical derivatization–assisted liquid chromatography-electrospray ionization-tandem mass spectrometry method

Chong-Xin Kang,Ru-Ting Fan,Hua-Ming Xiao,Xian Wang

Rationale Assessing estrogen concentrations in biological systems can provide valuable information on physiological processes, which is crucial for the early diagnosis of many diseases. Because estrogens are present in the human body in low concentrations and in a wide dynamic range, analytical methods with high sensitivity and specificity are required for their determination in complex biological matrices. Methods To discover an appropriate derivatization reagent for estrogen mass spectrometry (MS) analysis, we compared five sulfonyl chloride derivatization reagents, namely 3-methyl-8-quinolinesulfonyl chloride (MQSCl) and 8-quinolinesulfonyl chloride (QSCl), 1-methyl-1 H -pyrazole-4-sulfonyl chloride, 1,2-methyl-imidazole-5-sulfonyl chloride, and dansyl chloride. By selecting the derivatization reagent with the best performance, we developed and validated a novel chemical derivatization–assisted-liquid chromatography-electrospray ionization-tandem mass spectrometry (CD-LC-ESI-MS/MS) method to simultaneously determine the concentrations of estrone, estradiol, and estriol (E1, E2, and E3) in human serum. Results It was found that among the five investigated reagents, MQSCl-derivatized estrogens presented the highest sensitivity using LC-ESI-MS/MS. Based on this discovery, MQSCl was chosen to derivatize the analyzed estrogens to assist LC-ESI-MS/MS analysis. The limit of quantification of E1, E2, and E3 was measured as 2.7, 4.6, and 5.1 pg/mL, respectively. Inter- and intra-day precision, expressed as the coefficient of variation, was shown to be lower than 13.2% for all concentrations. The mean recovery was 72.4% overall, with good reproducibility at low, medium, and high concentrations in the calibration range. Conclusions The developed method was successfully applied to the quantitative determination of estrogens in clinical human serum from pediatric and adult women, demonstrating the suitability of estrogen analysis in the biological matrix at low concentration (pg/mL).

研究领域: 分析化学 · 临床化学 · 质谱分析
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。