文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

5 项

设置提升方向
Mn3(PO4)2
SENSORS AND ACTUATORS B-CHEMICAL · 2021 · IF 7.46

Biomineralized Mn3(PO4)2/aptamer nanosheets for enhanced electrochemical determination of C-reactive protein

Xiaofeng Tan,Ximei Sun,Yan Li,Yuting Zeng,Jinding Gong,Ziyu Wang,Yuhao An,He Li

Bio-inspired enzyme–inorganic hybrid nanomaterials are extensively employed for biological applications owing to their capability of enhancing enzyme activity and stability compared with free counterpart. They play a vital role in signal output and amplification during bioassay, but usually suffer from deactivation and costing problems, which motivates us to seek a more robust signal generation pattern. The coordination interaction between metal ions and amide groups in enzyme drives the evolution of various morphology and structure. Inspired by this, C-reactive protein (CRP) aptamer, with amide groups in their nucleobases, is introduced as an organic part serving as a linker and biorecognition unit to prepare aptamer-inorganic hybrid nanosheets, and be applied for CRP detection. Unlike using organic enzymes as a signal enhancer, the inorganic part, Mn 3 (PO 4 ) 2 , is exploited for generating and transducing firm current signals, which stem from electrochemical active molybdophosphate precipitates reacted by phosphate and external molybdate. This enzyme-free electrochemical aptasensor based on biomineralized Mn 3 (PO 4 ) 2 /aptamer exhibits an excellent detection performance for CRP. And the reliability is also acceptable compared to the traditional immunoturbidimetric method at the hospital, suggesting our method good feasibility for clinical diagnosis.

CAS / MDL: 62-31-7
研究领域: 生物传感器 · 纳米技术 · 电化学 · 生物医学工程
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
RSC Advances · 2016 ·Vol. 6 ·期 97 ·95199-95203 · IF 3.289

In situ synthesis and analytical investigation of porous Hb–Mn3(PO4)2 hybrid nanosheets and their biosensor applications

Shi-Yu Lu,Sheng-Hui Liao,Shu-Juan Bao,Meng Jin,Bo Weng,Chang-Ming Li

The excellent selectivity and anti-interference ability of enzyme-based biosensors have attracted considerable attention by researchers. However, the short lifetime, difficult electron transfer, and easily leak from the supporting materials restrict the practical applications of enzyme. In this study, an enzyme–inorganic hybrid biosensor constructed from slack Hb–Mn3(PO4)2·3H2O nanosheets was prepared by a simple and effective in situ immobilization method. Designed as an H2O2 sensor, it exhibits a fast electron transfer rate constant (ks = 4.16 s−1), an ultra-wide linear range for H2O2 detection (20 to 56 100 μM), and long life-time (85% of initial response after 29 days), which may be attributed to the effective immobilization of the enzyme and the good biocompatibility of Mn3(PO4)2·3H2O. For the detection of a real sample, the range of recovery of our designed biosensor was around 98.2–102.6%, confirming that our proposed method presents a promising immobilization enzyme-based biosensor for use in practical applications.

研究领域: 生物化学 · 分析化学 · 材料科学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
Nano Research · 2020 ·Vol. 14 ·期 3 ·879-886 · IF 8.183

2-D/2-D heterostructured biomimetic enzyme by interfacial assembling Mn3(PO4)2 and MXene as a flexible platform for realtime sensitive sensing cell superoxide

Zhao Shen Fei,Hu Fang Xin,Shi Zhuan Zhuan,Fu Jing Jing,Chen Yue,Dai Fang Yin,Guo Chun Xian,Li Chang Ming

It is critical for fabricating flexible biosensors with both high sensitivity and good selectivity to realize real-time monitoring superoxide anion (O 2 •− ), a specific reactive oxygen species that plays critical roles in various biological processes. This work delicately designs a Mn 3 (PO 4 ) 2 /MXene heterostructured biomimetic enzyme by assembling two-dimensional (2-D) Mn 3 (PO 4 ) 2 nanosheets with biomimetic activity and 2-D MXene nanosheets with high conductivity and abundant functional groups. The 2-D nature of the two components with strong interfacial interaction synergistically enables the heterostructure an excellent flexibility with retained 100% of the response when to reach a bending angle up to 180°, and 96% of the response after 100 bending/relaxing cycles. It is found that the surface charge state of the heterostructure promotes the adsorption of O 2 •− , while the high-energy active site improves electrochemical oxidation of O 2 •− . The Mn 3 (PO 4 ) 2 /MXene as a sensing platform towards O 2 •− achieves a high sensitivity of 64.93 µA·µM −1 ·cm −2 , a wide detection range of 5.75 nM to 25.93 µM, and a low detection limit of 1.63 nM. Finally, the flexible heterostructured sensing platform realizes real-time monitoring of O 2 •− in live cell assays, offering a promising flexible biosensor towards exploring various biological processes.

研究领域: 生物传感器 · 材料科学 · 电化学 · 生物医学工程
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
MICROCHIMICA ACTA · 2017 ·Vol. 184 ·期 4 ·1177-1184 · IF 4.58

Controlled synthesis of Mn3(PO4)2 hollow spheres as biomimetic enzymes for selective detection of superoxide anions released by living cells

Wang Min-Qiang,Ye Cui,Bao Shu-Juan,Xu Mao-Wen

The authors have synthesized nanostructured manganese(II) phosphate hollow spheres [Mn 3 (PO 4 ) 2 HS] with tunable pore structure by using a micro-emulsion method. These, if deposited on a glassy carbon electrode (GCE), are shown to be a viable material for electrochemical sensing of superoxide (radical) anion (O 2 ˙ − ) at a typical working voltage of 0.7 V (vs. SCE). Hence, they act as biomimetic enzymes that allow for the determination of O 2 ˙ − with a very low detection limit (1.35 nM), wide linear range (5 nM to 0.4 mM), and good long-term stability. The modified GCE was applied in-situ to the electrochemical determination of O 2 − that is released from human malignant melanoma cells and normal keratinocyte, and it showed excellent real time analytical capability. In our perception, the use of this material offers exciting opportunities in terms of implementing nanoscale transition metal phosphates as biomimetic enzymes in enzyme-free diagnostic sensors. Conceivably, these will offer higher sensitivity and longer durability than assays based on the use of natural enzymes. Micro-emulsion method-derived nanostructured manganese(II) phosphate hollow spheres [Mn 3 (PO 4 ) 2 HS] as biomimetic enzymes to sensitively detect superoxide anions released by living cells.

研究领域: 材料科学 · 分析化学 · 生物医学工程
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
BIOSENSORS & BIOELECTRONICS · 2017 · IF 7.78

Efficient in situ growth of enzyme-inorganic hybrids on paper strips for the visual detection of glucose

WanYun Li,ShiYu Lu,ShuJuan Bao,ZhuanZhuan Shi,Zhisong Lu,ChangMing Li,Ling Yu

A visual colorimetric microfluidic paper-based analytical device (μPAD) was constructed following the direct synthesis of enzyme-inorganic hybrid nanomaterials on the paper matrix. An inorganic solution of MnSO 4 and KH 2 PO 4 containing a diluted enzyme (glucose oxidase, GOx) was subsequently pipetted onto cellulose paper for the in situ growth of GOx@Mn 3 (PO 4 ) 2 hybrid functional materials. The characterization of the morphology and chemical composition validated the presence of hybrid materials roots in the paper fiber, while the Mn 3 (PO 4 ) 2 of the hybrid provided both a surface for enzyme anchoring and a higher peroxidase-like catalytic activity as compared to the Mn 3 (PO 4 ) 2 crystal that was synthesized without enzyme modulation. This new approach for the in situ growth of an enzyme-inorganic hybrid on a paper matrix eliminates centrifugation and the dry process by casting the solution on paper. The sensing material loading was highly reproducible because of the accuracy and stability of pipetting, which eventually contributed to the reliability of the μPAD. The self-assembled natural and artificial enzyme hybrid on the μPADs specifically detected glucose from a group of interferences, which shows great specificity using this method. Moreover, the colorimetric signal exhibited detection limitation for glucose is 0.01   mM, which lies in the physiological range of glucose in biological samples.

研究领域: 分析化学 · 生物传感器 · 材料科学 · 生物技术
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。