文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
NH2-ZIF-8@Cu2
SENSORS AND ACTUATORS B-CHEMICAL · 2025 · IF 7.7

On-Site AFB1 detection in food via dual-equipped NH2-ZIF-8@Cu2+ and core-shell UCNPs embedded in SA-PAM hydrogel

Huanhuan Li,Yu Wu,Xorlali Nunekpeku,Yuhan Yang,Jingsa Zhao,Wei Sheng,Yuexia Wang

The increasing presence of Aflatoxin B 1 (AFB 1 ) residues in food continues to raise significant public health concerns. Herein, we designed an upconversion-based sensor integrated into an alginate-polyacrylamide (SA-PAM) hydrogel for on-site AFB 1 detection in food. First, core-shell upconversion nanoparticles (CSUCNPs) with enhanced fluorescence were modified with complementary DNA (cDNA), forming signal probes known as CSUCNPs-cDNA. Simultaneously, NH 2 -ZIF-8@Cu 2+ with a high surface area and specific affinity for aptamer was synthesized using a one-pot method. This was then modified with an AFB 1 -specific aptamer, forming the capture probe Apt-ZIF-8@Cu 2+ . Using base pairing, CSUCNPs-cDNA and Apt-ZIF-8@Cu 2+ were hybridized into sensing probes (CSUCNPs-ZIF-8@Cu 2+ ), which were embedded into SA-PAM hydrogels as stable sensor carrier. Furthermore, the SA-PAM hydrogel showed a reduced swelling ratio of 1.68–1.80 in water and phosphate buffer solution(s) (PBS), which improves stability. In the presence of AFB 1 , the aptamer selectively binds the AFB 1 , increasing electrostatic repulsion between CSUCNPs-cDNA and Apt-ZIF-8@Cu 2+ . This disrupts Förster resonance energy transfer (FRET), resulting in a pronounced “signal-on” fluorescence. This sensor achieves AFB 1 diffusion through the SA-PAM hydrogel, FRET disruption and upconversion signal stabilization within 18 min, faster than traditional methods. Under optimized conditions, the sensor exhibited a clear linear correlation between fluorescence intensity and the logarithm of AFB 1 concentration ranging from 0.1 to 100 µg/kg ( R ² = 0.994), with a detection limit as low as 0.08 µg/kg. Besides, its performance was further validated through tests on spiked wheat, corn, peanut, and water, demonstrating high accuracy and reproducibility with relative standard deviation (RSD) below 3.63 % and recoveries of 85.88–98.04 %.

研究领域: 食品安全 · 分析化学 · 纳米技术 · 生物传感器 · 毒素检测
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。