文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
NH2-Zr-MOF@Thi
MICROCHEMICAL JOURNAL · 2024 · IF 4.9

Construction of a sensitive electrochemical biosensor for detecting protein kinase A activity based on NH2-Zr-MOF@Thi signal amplification

Xue Men,Rong Li,Aiwen Su,Yanli Zhang,Lian-Xun Gao,Chengxin Wu,Hongbin Wang,Wenrong Yang,Pengfei Pang

Protein kinase A (PKA) plays a significant role in the regulation of biological activities by the phosphorylation of the specific proteins or substrate peptides. The highly sensitive and reusable electrochemical biosensor has been developed to detect PKA activity based on the specific coordination between Zr 4+ and phosphate group. In this strategy, the specially designed substrate peptide can be anchored on the surface of gold electrode by Au-S bond. In the presence of adenosine triphosphate (ATP) and PKA, the substrate peptide is phosphorylated. Due to the large surface area of MOF and rich Zr 4+ active sites, signal molecule Thionine (Thi) can be absorbed into the cavity of NH 2 -Zr-MOF by the electrostatic interaction to form NH 2 -Zr-MOF@Thi signal probe. The phosphorylated peptide is linked to NH 2 -Zr-MOF@Thi probe because of the strong coordination interaction between Zr 4+ and phosphate group. Therefore, the number of Thi close to the electrode surface is increased and the response signal experiences amplification, markedly enhancing the sensitivity of the detection of PKA activity, which provides an excellent electrochemical sensing platform for PKA activity detection. The response signal of the electrochemical biosensor is proportional to the logarithm of PKA concentration, ranging from 0.05 U mL −1 to 100 U mL −1 , and the limit of detection of this biosensor for PKA is 0.017 U mL −1 when the signal-to-noise ratio is 3. In particular, the proposed method can selectively distinguish the target from other interferents, and can be used to screen potential small molecule inhibitors and detect PKA activity in complex cell samples. Therefore, the developed electrochemical biosensor can be used as a new way for the determination of PKA activity and the screening of its inhibitors in the future.

研究领域: 生物化学 · 分析化学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。