文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

2 项

设置提升方向
NO2干扰
ELECTROCHIMICA ACTA · 2019 · IF 5.383

Mixed-potential type NH3 sensor based on CoWO4-PdO sensing electrode prepared by self-demixing

Wiewei Meng,Ling Wang,Yuehua Li,Huizhu Zhou,Zhangxing He,Wei Meng,Lei Dai

CoWO 4 -PdO dual phase composites were successfully prepared by self-demixing of the precursor CoPd x WO 4+x (x = 0, 2%, 5%, 10%) calcined at 800 °C and used as sensing electrodes for mixed-potential type NH 3 sensors based on yttria stabilized-zirconia (YSZ) electrolyte. The materials were characterized by X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS) and Field-emission scanning electron microscopy (FESEM), respectively. NH 3 response performance of the sensors to different concentrations of NH 3 (20–300 ppm) was evaluated at 350–500 °C. It was found that the sensors attached with CoWO 4 -PdO sensing electrode are much more sensitive to NH 3 than the CoWO 4 -based sensor. Among them, CoWO 4 -5%PdO based sensor gives the highest sensitivity (−76.8 mV/decade at 400 °C), the response signals (Δ V ) of the sensor vary linearly with the logarithm of the NH 3 concentrations in the range of 50–300 ppm at a given temperature. The sensor also exhibits well reproducibility, stability and long-term stability. Furthermore, compared with CoWO 4 -based sensor, the introduction of PdO in CoWO 4 makes the interference of NO 2 on the sensor significantly reduced from 100% to 50%, which is attributed to the fact that the second phase PdO depresses the adsorption of NO 2 .

研究领域: 材料科学 · 传感技术
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
JOURNAL OF THE ELECTROCHEMICAL SOCIETY · 2022 ·Vol. 169 ·期 8 ·087505 · IF 4.386

Enhancement of Ammonia Sensors Using In2O3 Sensing Electrode by Adjusting Particle Size and NiCo2O4 Reference Electrode

Lin Yang,Chunping Wu,Yiran Zhang,Bang Xiao,Anqi Jiao,Ke Li,Ting Chen,Reggie Zhan,He Lin

A mixed potential ammonia sensor using In2O3 sensing electrode was prepared, and its sensing performance was enhanced by adjusting particle size with calcination heating rate as well as the utilization of NiCo2O4 reference electrode. It was found that the sensor with a calcination heating rate of 2 °C min−1 had the best performance, with a sensitivity of −61.27 mV decade−1 at 525 °C, and the TEM results showed that the average particle size was 70.36 nm. Furthermore, the sensor exhibited good stability against oxygen concentration fluctuation. The results also indicated that the mixed potential has a linear relationship with the logarithm of NH3 concentration, suggesting that the ammonia sensors in this study conform to the mixed potential theory. To address the issue that most ammonia sensors are susceptible to NO2 interference, NiCo2O4 was used as reference electrode to replace the Pt reference electrode, which could greatly offset the response of NO2 and improve the sensors selectivity. In summary, the developed In2O3/YSZ/NiCo2O4 sensor exhibited a great potential for NH3 monitoring in SCR systems.

研究领域: 材料科学 · 电化学 · 环境监测
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。