JOURNAL OF MEMBRANE SCIENCE
·
2018
·
IF 6.578
Xinru Zhang,Tao Zhang,Yonghong Wang,Jinping Li,Chengcen Liu,Nanwen Li,Jiayou Liao
Mixed-matrix membranes (MMMs) for CO 2 /N 2 separation were prepared by incorporating nickel-substituted ZIF-8 (Zn/Ni-ZIF-8) into a polyether-block-amide (PEBA2533) polymer, in which the Zn and Ni ions in Zn/Ni-ZIF-8 have different affinities for CO 2 based on π-complexation; these MMMs exhibited exceptional molecular sieving properties compared to ZIF-8-PEBA MMMs. Scanning electron microscopy revealed that Zn/Ni-ZIF-8 nanoparticles were small and uniformly distributed within the PEBA, and attenuated total reflectance Fourier-transform infrared spectroscopy revealed good interfacial compatibility between the Zn/Ni-ZIF-8 and PEBA; consequently these MMMs exhibited excellent mechanical properties . The 10% Zn/Ni-ZIF-8-PEBA MMM showed a high CO 2 permeability of 321 Barrer, and a CO 2 /N 2 selectivity of 42.8 at 2 bar; these values were much higher than those of the 10% ZIF-8-PEBA MMM (266 Barrer and 33.8, respectively). We assume that different metal-ion affinities towards CO 2 resulted in the asymmetric adsorption/desorption behaviour of these MMMs, which led to a significantly higher permselectivity for the Zn/Ni-ZIF-8-PEBA MMM. The MMM loaded with 10% Zn/Ni-ZIF-8 exhibited long-term CO 2 -separation-performance stability under mixed-gas conditions, with a CO 2 permeability of 282 Barrer and a CO 2 /N 2 selectivity of 42.7. Moreover, the permselectivity of the 10% Zn/Ni-ZIF-8-PEBA MMM under pure-gas condition surpassed Robeson's upper bound reported in 2008.
研究领域:
材料科学
·
环境工程
✓ 已验证
产品关联
DOI
高影响因子
SEPARATION AND PURIFICATION TECHNOLOGY
·
2025
·
IF 9
Chuanqi Zhang,Xiaomei Cheng,Ruirui Zhao,Mengxian Fu,Meifang Wang,Zhiming Chen,Changfang Zhang,Xiangzi Li
The integration of metal–organic framework (MOF) materials with magnetic cores not only serves as an effective adsorbent but also facilitates the recovery post-adsorption. In this study, we synthesized Ni@ZIF-8 composite nanotubes by introducing ZIF-8 onto the surface of Ni nanotubes, which were used as adsorbents for antibiotic removal. The Ni@ZIF-8 composite nanotubes exhibited high-efficiency and recyclable antibiotic adsorption, with the maximum adsorption capacities for tetracycline (TC) and cefixime (CFX) reaching 770.2 and 428.2 mg·g −1 , respectively. The Ni nanotubes, acting as magnetic cores, facilitated magnetic recovery after adsorption. Furthermore, the introduction of ZIF-8 not only increased the surface roughness of the composite but also incorporated a significant number of functional groups. The pseudo-second-order model, Langmuir model and intra-particle diffusion models provided better fits to the isotherm and kinetic data of the two antibiotics. Density functional theory (DFT) calculations results indicate that the π-π interactions dominate the adsorption process of both TC and CFX onto ZIF-8. And the electrostatic potential (ESP) calculations and interaction analysis indicate that the Ni atom enhances the adsorption behavior through π-π interactions between the benzene ring or carbonyl group of the two antibiotics and the imidazole of ZIF-8. This research offers a novel approach for the removal of antibiotics from contaminated water and environmental remediation using magnetic core-MOF composite materials.
研究领域:
环境科学
·
材料科学
✓ 已验证
产品关联
DOI
高影响因子
CHEMICAL ENGINEERING JOURNAL
·
2020
·
IF 10.652
Ihtisham Ul Haq,Shen Hui Li,Hong-Gang Zhen,Rehan Khan,Ao-Shuai Zhang,Zhi-Ping Zhao
For separating 1, 3-butadiene (BD) from BD/N 2 mixture, among numerous studied metal–organic frameworks-based adsorbents, Ni-ZIF-8 was comparatively selected here based on intelligent gravimetric analysis, simulation studies, facile synthesis, and very good IAST selectivity. Experimental results showed good butadiene uptake capacity of Ni-ZIF-8 of 7.41 mol/kg, which is 42% higher than pure ZIF-8. Additionally, Ni-ZIF-8 exhibits IAST selectivities of 2826 and 3302 at 0.1 bar, at 25 and 45 °C respectively, for 20% BD/N 2 adsorption. The molecular simulation results showed that Ni-ZIF-8 has binding energies of 65.25, 9.54 kJ/mol, while ZIF-8 has 56.07, 15.03 kJ/mol for butadiene, and nitrogen, respectively. This strongly supported the experimental results. To the best of our knowledge, Ni-ZIF-8 showed the best working capacity of 5.91 mol/kg for butadiene among all the reported adsorbents. Moreover, dynamic adsorption experiments revealed that butadiene could be recovered from BD/N 2 mixtures at room temperature, suggesting great potential for industrial BD/N 2 separation.
研究领域:
材料科学
·
化学工程
✓ 已验证
产品关联
DOI
高影响因子
CHEMOSPHERE
·
2022
·
IF 8.943
Tao Zhang,Pan Wu,Gary Owens,Zuliang Chen
Since ofloxacin (OFX) is one of many common antibiotics, which effluxes into aquatic environment in relatively high concentration, it has become of significant environmental concern due to the potential for increased antibiotic resistance. In this study, an innovative functional Fe/Ni@ZIF-8 composite was successfully used for the Fenton-like oxidation of OFX, with a OFX removal efficiency >98% under optimal conditions. FTIR analysis confirmed that OFX removal occurred via adsorption to Fe/Ni@ZIF-8 by a combination of π-π bond intercalation and electrostatic interaction, while XPS revealed that the Fe/Ni NPs in Fe/Ni@ZIF-8 were also involved in oxidation. Furthermore, LC-MS analysis identified the presence of several OFX degradation products post exposure, which indicted that Fe/Ni NPs in Fe/Ni@ZIF-8 reacted with H 2 O 2 to form •OH, leading to Fenton-like oxidation of OFX. Thus overall, OFX removal by Fe/Ni@ZIF-8 involved both adsorption to ZIF-8 and Fenton-like oxidation by Fe/Ni NPs. A synergistic mechanism for OFX removal by Fe/Ni@ZIF-8 was thus proposed. The removal efficiency of the synthesized catalysts remained high (above 65%) even after a 5th reuse cycle, which reflected the high stability of Fe/Ni@ZIF-8. Overall, this study demonstrated that Fe/Ni@ZIF-8 had significant potential for the removal of OFX from wastewaters with a removal efficiency >90%.
研究领域:
环境科学
·
材料科学
✓ 已验证
产品关联
DOI
PubMed
高影响因子
JOURNAL OF APPLIED ELECTROCHEMISTRY
·
2023
·
IF 2.9
Zhan Ke,Du Yongkun,Liu Qingqing,Cui Chenxu,Xing Guangxu,Li Shanshan,Ren Hongtao,Wang Fan,Xu Chao,Wang Na
Wheat gliadin is thought to be the main cause of wheat allergy leading to celiac disease. In this study, we reported an electrochemical immunosensor based on AuNPs/Zn/Ni-ZIF-8-800@graphene for simple, efficient, and sensitive detection of gliadin. A monoclonal antibody against gliadin were prepared by hybridoma technique. Zn/Ni-ZIF-8-800 with high stability was prepared by using zinc–nickel bimetallic organic framework MOFs, and graphene and gold nanoparticles with large surface area and excellent conductivity were introduced. Chitosan was used as a binder to fixed the composite on the surface of glassy carbon electrode. The fabricated materials and the corresponding sensors were comprehensively characterized by X-ray diffractometer, scanning electron microscope, transmission electron microscopy, Fourier transform infrared spectroscopy, Brunauer–Emmett–Teller, and cyclic voltammetry analyses. Under the optimal conditions, the linear range of the electrochemical immunosensor was 0.1–100 μg mL −1 , and the detection limit was 0.950 μg mL −1 . In addition, the fabricated sensor exhibited high selectivity and long-term stability. The recovery test showed that the prepared sensor was suitable for the detection of gliadin in real food and feed, exhibiting great promising of the developed sensor in practical application. Graphical abstract
研究领域:
分析化学
·
生物化学
·
材料科学
·
食品科学
·
免疫学
✓ 已验证
DOI
高影响因子