文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
NiCoMn-OH
JOURNAL OF COLLOID AND INTERFACE SCIENCE · 2022 · IF 9.965

In situ growth of ZIF-67-derived nickel-cobalt-manganese hydroxides on 2D V2CTx MXene for dual-functional orientation as high-performance asymmetric supercapacitor and electrochemical hydroquinone sensor

Tingting Yu,Shaobin Li,Li Zhang,Fengbo Li,Jianxin Wang,Hong Pan,Deqing Zhang

Designing dual-functional electrode materials for supercapacitors and pollutant sensors has attracted great interest from researchers for urgent demand in green energy and the environment. In this work, a novel electrode material V 2 CT x @NiCoMn-OH was successfully constructed for dual-functional orientation via a two-step synthesis strategy, in which the NiCoMn-OH with a three-dimensional (3D) hollow structure was fabricated by employing ZIF-67 as a template and simple anion exchange and composited with the two-dimensional (2D) layered V 2 CT x MXene. The intercalation of NiCoMn-OH can effectively limit the self-accumulation of V 2 CT x MXene nanosheets and build a 3D cross-linked hollow structure, thereby broadening the ion transport channel, exposing more active sites of V 2 CT x @NiCoMn-OH, and simultaneously improving the conductivity of NiCoMn-OH. Benefiting from the unique 3D cross-linked hollow structure, the optimized V 2 CT x @NiCoMn-OH-20 electrode material exhibits an excellent specific capacitance of 827.45 C g −1 at 1 A g −1 . Furthermore, the electrode material has excellent capacitance retention of 88.44% after 10,000 cycles. Moreover, the V 2 CT x @NiCoMn-OH-20//AC ASC device displays a high energy density of 88.35 Wh kg −1 as well as high power density of 7500 W kg −1 during operation. Additionally, the V 2 CT x @NiCoMn-OH-20 exhibited excellent electrocatalytic performance in the detection of hydroquinone, including the low detection limit of 0.559 μM (S/N = 3) and the wide linear range of 2–1050 μM. Therefore, the prepared V 2 CT x @NiCoMn-OH-20 has great potential applications in the fields of supercapacitors and hydroquinone sensors.

研究领域: 材料科学 · 能源技术 · 环境科学 · 电化学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。