文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

2 项

设置提升方向
OPLI
ANALYTICAL CHEMISTRY · 2024 · IF 6.7

Development of a Methodology Based on Optical Interferometry for Measuring Fibrinolytic Activity

Liming Liu,Ning Ma,Lu Wang,Yu Zhang,Yi-Zhen Wan,Tianze Wang,Weiping Qian

Fibrinolytic activity assay is particularly important for the detection, diagnosis, and treatment of cardiovascular disease and the development of fibrinolytic drugs. A novel efficacious strategy for real-time and label-free dynamic detection of fibrinolytic activity based on ordered porous layer interferometry (OPLI) was developed. Fibrin or a mixture of fibrin and plasminogen (Plg) was loaded into the highly ordered silica colloidal crystal (SCC) film scaffold to construct a fibrinolytic response interference layer to measure fibrinolytic activity with different mechanisms of action. Fibrinolytic enzyme-triggered fibrinolysis led to the migration of interference fringes in the interferogram, which could be represented by optical thickness changes (ΔOT) tracked in real time by the OPLI system. The morphology and optical property of the fibrinolytic response interference layer were characterized, and the Plg content in the fibrinolytic response interference layer and experimental parameters of the system were optimized. The method showed adequate sensitivity for the fibrinolytic activity of lumbrokinase and streptokinase, with wide linear ranges of 12–6000 and 10–2000 U/mL, respectively. Compared with the traditional fibrin plate method, it has a lower detection limit and higher linearity. The whole kinetic process of fibrinolysis by these two fibrinolytic drug models was recorded in real time, and the Michaelis constant and apparent kinetic parameters were calculated. Importantly, some other blood proteins were less interfering with this system, and it showed reliability in fibrin activity detection in real whole blood samples. This study established a better and more targeted research method of in vitro fibrinolysis and provided dynamic monitoring data for the analysis of fibrinolytic activity of whole blood.

研究领域: 生物医学工程 · 心血管疾病 · 药物开发 · 干涉测量 · 纤溶
✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
LANGMUIR · 2023 · IF 3.9

Ordered Porous Layer Interferometry for Dynamic Observation of Non-Specific Adsorption Induced by 1-Ethyl-3-(3-(dimethylamino)propyl) Carbodiimide

Yu Zhang,Lu Wang,Ning Ma,Yizhen Wan,Xueyi Zhu,Weiping Qian

Nonspecific adsorption (NSA) seems to be an impregnable obstacle to the progress of the biomedical, diagnostic, microelectronic, and material fields. The reaction path of bioconjugation can alter the surface charge distribution on products and the interaction of bioconjugates, an ignored factor causing NSA. We monitored exacerbated NSA introduced by a 1-ethyl-3-(3-(dimethylamino)propyl) carbodiimide (EDC) addition reaction, which cannot be resistant to bovine serum albumin (BSA) or polyethylene glycol (PEG) antifouling coating and Tween-20. And the negative effects can be minimized by adding as low as 7.5 × 10–6 M N-hydroxysulfosuccinimide (sulfo-NHS). We applied ordered porous layer interferometry (OPLI) to sensitively evaluate the NSA that is difficult to measure on individual particles. Using the silica colloidal crystal (SCC) film with Fabry–Perot fringes as in situ and real-time monitoring for the NSA, we optimized the surface chemistry to yield a conjugate surface without variational charge distribution. In this work, we propose a novel approach from the perspective of the reaction pathway to minimize the NSA of solely EDC-induced chemistry.

CAS / MDL: 393781-70-9
研究领域: 生物医学工程 · 材料科学 · 分析化学 · 表面化学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。