文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

2 项

设置提升方向
PANI水凝胶
ACS Applied Materials & Interfaces · 2014 · IF 5.9

Enhanced Sensitivity and Stability of Room-Temperature NH3 Sensors Using Core–Shell CeO2 Nanoparticles@Cross-linked PANI with p–n Heterojunctions

Lingling Wang,Hui Huang,Songhua Xiao,Daoping Cai,Yuan Liu,Bin Liu,Dandan Wang,Chenxia Wang,Han Li,Yanrong Wang,Qiuhong Li,Taihong Wang

We report a room-temperature NH3 gas sensor with high response and great long-term stability, including CeO2 NPs conformally coated by cross-linked PANI hydrogel. Such core–shell nanocomposites were prepared by in situ polymerization with different weight ratios of CeO2 NPs and aniline. At room temperature, the nanohybrids showed enhanced response (6.5 to 50 ppm of NH3), which could be attributed to p–n junctions formed by the intimate contact between these two materials. Moreover, the stability was discussed in terms of phytic acid working as a gelator, which helped the PANI sheath accommodate itself and enhance the mechanical strength and chemical stability of the sensors by avoiding “swelling effect” in high relative humidity. The sensors maintained its sensing characteristic (response of ca. 6.5 to 50 ppm of NH3) in 15 days. Herein, the obtained results could help to accelerate the development of ammonia gas sensor.

研究领域: 材料科学 · 传感器技术
✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
ACS Applied Materials & Interfaces · 2021 · IF 9.229

Capacitive Pressure Sensors Containing Reliefs on Solution-Processable Hydrogel Electrodes

Hongwei Zhou,Mingcheng Wang,Xilang Jin,Hanbin Liu,Jialiang Lai,Haotian Du,Weixing Chen,Aijie Ma

Highly sensitive capacitive-type pressure sensor has been achieved by fabricating reliefs on solution-processable hydrogel electrodes. Hybrid PVA/PANI hydrogels (PVA, poly(vinyl alcohol); PANI, polyaniline) with a fully physically cross-linked binary network are selected as the electrodes of the pressure sensors. On the basis of the solution processability, reliefs are fabricated on the surface of PVA/PANI hydrogel electrodes by a template method. The gauge factor (GF) is enhanced by introducing reliefs and regulated by controlling the composition and relief dimension of hydrogel electrodes. The optimized pressure sensor containing reliefs achieves the highest GF of 7.70 kPa–1 and a sensing range of 0–7.4 kPa. Furthermore, the freezing and drying problems of the hydrogel sensors are overcome by introducing a binary solvent of water/glycerol and the pressure sensing ability at −18 °C has been achieved. Finally, monitoring of various pressures in daily life, such as joint bending, blowing, and brush writing, is demonstrated using such pressure sensors.

CAS / MDL: 9002-89-5
研究领域: 材料科学 · 生物医学工程
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。