文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
PCR产物
ANALYTICAL CHEMISTRY · 2017 · IF 6.32

Integrated Graphene Oxide Purification-Lateral Flow Test Strips (iGOP-LFTS) for Direct Detection of PCR Products with Enhanced Sensitivity and Specificity

Shanglin Li,Yin Gu,Yi Lyu,Yan Jiang,Peng Liu

An integrated graphene oxide purification-lateral flow test strip (iGOP-LFTS) was developed for on-strip purifying and visually detecting polymerase chain reaction (PCR) products with an improved sensitivity as well as a more stringent specificity. PCR products amplified with a pair of biotin- and digoxin-labeled primers were directly pipetted onto GO pads, on which graphene oxide selectively adsorbed residual primers and primer-dimers with the aid of a running buffer containing MgCl2 and Tween 20. By stacking up three GO pads to increase the surface area for adsorption, 83.4% of double-stranded DNA with a length of 30 bp and 98.6% of 20-nt primers could be removed from a 10-μL DNA mixture. Since no primers interfered with detection, the increase of the sample loading volume from 5 to 20 μL could improve the signal-to-noise ratio of the test line 1.6 fold using the iGOP-LFTS while no changes were observed using the conventional LFTS. The limit of detection of the iGOP-LFTS was determined to be 30 copies of bacteriophage λ-DNA with naked eyes and this limit could be further decreased to 3 copies by loading 20 μL of the sample, which corresponded to a 1000-fold improvement compared to that of the LFTS detected by naked eyes. When the ImageJ analysis was employed, a 100-fold decrease of the detection limit can be obtained. In addition, due to the removal of the primer-dimers, the dim test line observed in the negative control of the LFTS was eliminated using the iGOP-LFTS. A mock clinical specimen spiked with defective HIV-1 (human immunodeficiency virus) viruses was successfully analyzed using a two-step reverse transcription-PCR with 30 amplification cycles followed by the iGOP-LFTS detection. These significant improvements were achieved without introducing any additional hands-on operations and instrumentations.

研究领域: 分子生物学 · 分析化学 · 生物医学工程 · 病毒学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。