文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
PDMS微柱阵列
NEW JOURNAL OF CHEMISTRY · 2017 ·Vol. 41 ·期 13 ·5429-5435 · IF 3.269

Platinum porphyrin/3-(trimethoxysily)propylmethacrylate functionalized flexible PDMS micropillar arrays as optical oxygen sensors

Yongyun Mao,Qian Zhao,Tingting Pan,Jiayan Shi,Shimei Jiang,Meiwan Chen,Bingpu Zhou,Yanqing Tian

Integrating an oxygen-sensitive probe (OSP) onto a three-dimensional (3D) microstructure substrate is a plausible technique to significantly improve the sensitivity of oxygen sensors. Despite the fact that polydimethylsiloxane (PDMS) matrices are regarded as the ideal sensory support, there are still no reports on an OSP functionalized flexible PDMS-based micropillar array (PDMS-MPAs) film as an optical oxygen sensor with capabilities to efficiently improve the sensor's overall performance, e.g. sensitivity, detection limit and stability against photo-bleaching. Herein, we reported the covalent bonding of a functional copolymer of platinum porphyrin (PtTPP)/3-(trimethoxysily)propylmethacrylate (PtTPP/TPMA) as the OSP on the surface of hydroxyl-modified PDMS-MPAs through a “grafting reaction” between PtTPP/TPMA and PDMS-MPAs. The homogeneous dispersion and well-isolated arrangement of the PtTPP/TPMA OSP on the 3D PDMS-MPA surface can ensure that the grafted OSP efficiently quenches the oxygen molecules. Consequently, the 3D PtTPP/TPMA-PDMS-MPA sensor film gives rise to a high fluorescence quenching efficiency of about 95% at 1 atm O2 (I0/I100 = 23) and 96% in aqueous solution (I0/IO2satu = 16) with an excellent linear Stern–Volmer plot (ksv = 0.1 h Pa−1, R2 = 0.997 in gas atmosphere and ksv = 12.8 mmol−1 L, R2 = 0.999 in aqueous solution, respectively), excellent reversibility and an ultra-low detection limit (4.7 μmol L−1) when compared with state-of-the-art PDMS-based oxygen sensors. Apart from the competitive sensitivity, the highly durable, reusable superiorities of the 3D PtTPP/TPMA-PDMS-MPA film can further facilitate the exploration and realization of the presented strategy for future oxygen sensor applications, such as the characterization of nearly anoxic systems in harsh environments.

CAS / MDL: 9001-37-0
研究领域: 材料科学 · 生物医学工程 · 化学传感
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。