文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

3 项

设置提升方向
PEI-CDs
SENSORS AND ACTUATORS B-CHEMICAL · 2019 · IF 6.393

A novel self-enhanced electrochemiluminescence sensor based on PEI-CdS/Au@SiO2@RuDS and molecularly imprinted polymer for the highly sensitive detection of creatinine

Nian Cao,Faqiong Zhao,Baizhao Zeng

In this work, a novel self-enhanced solid state electrochemiluminescence (ECL) platform, based on polyethyleneimine (PEI) capped CdS quantum dots (PEI-CdS QDs) as coreactant and [email protected] 2 @Ru(bpy) 3 2+ doped silica ( [email protected] 2 @RuDS) nanocomposite as ECL emitter, was constructed. The PEI-CdS QDs integrated double coreactant of PEI and CdS QDs, thus significantly promoted the ECL of [email protected] 2 @RuDS. Polyaniline hydrogel was introduced to boost the electron transfer and to improve the immobilization of PEI-CdS/ [email protected] 2 @RuDS. In addition, creatinine imprinted poly(o-aminophenol) film was electrodeposited on the PEI-CdS/ [email protected] 2 @RuDS surface as recognition element. Thus, the obtained sensor possessed high sensitivity, stability, reproducibility and selectivity for creatinine sensing. The change of ECL intensity and logarithm of creatinine concentration showed a good linear relationship in the range of 0.05 nM to 5 μM, and the detection limit was low to 0.02 nM. The sensor was applied to detect creatinine in human serum and urine samples, and the results were in good agreement with those of commercial enzyme-linked immunosorbent assay kit.

研究领域: 分析化学 · 纳米技术 · 生物传感器 · 材料科学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
MICROCHIMICA ACTA · 2018 ·Vol. 185 ·期 11 ·1-7 · IF 5.705

A ratiometric fluorometric heparin assay based on the use of CdTe and polyethyleneimine-coated carbon quantum dots

Liang Si-Si,Deng Xu,Fan Yao-Yao,Li Jun,Wang Man,Zhang Zhi-Qi

CdTe quantum dots (QDs) were integrated with polyethyleneimine-coated carbon dots (PEI-CDs) to form a dually emitting probe for heparin. The red fluorescence of the CdTe QDs is quenched by the PEI-CDs due to electrostatic interactions. In the presence of heparin, the blue fluorescence of PEI-CDs remains unaffected, while its quenching effect on the fluorescence of CdTe QDs is strongly reduced. A ratiometric fluorometric assay was worked out. The ratio of the fluorescences at 595 and 436 nm serves as the analytical signal. Response is linear in the concentration range of 50–600 ng·mL −1 (0.1–1.2 U·mL −1 ) of heparin. The limit of detection is 20 ng·mL −1 (0.04 U·mL −1 ). This makes the method a valuable tool for heparin monitoring during postoperative and long-term care. This assay is relatively free from the interference by other analogues which commonly co-exist with heparin in samples, and it is more robust than single-wavelength based assays. In the presence of heparin, the fluorescence of polyethyleneimine-coated carbon dots (PEI-CDs) at 436 nm remains unaffected, while its quenching effect on the fluorescence of CdTe at 595 nm is strongly reduced.

研究领域: 分析化学 · 生物医学工程 · 药物分析
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
SENSORS AND ACTUATORS B-CHEMICAL · 2020 · IF 7.1

A novel ratiometric molecularly imprinted electrochemiluminescence sensor for sensitive and selective detection of sialic acid based on PEI-CdS quantum dots as anodic coreactant and cathodic luminophore

Nian Cao,Faqiong Zhao,Baizhao Zeng

In this study, a novel potential-resolved ratiometric electrochemiluminescence (ECL) sensor, using Ru(bpy) 3 2+ doped TiO 2 nanoparticles (TiO 2 -Ru(bpy) 3 2+ NPs) with polyethyleneimine (PEI) capped CdS quantum dots (PEI-CdS QDs) as new ECL emitter unit and molecularly imprinted polymer (MIP) as recognition element, was proposed for the first time. Owing to the large specific surface area and porosity of TiO 2 NPs plentiful Ru(bpy) 3 2+ was well immobilized on them. The obtained TiO 2 -Ru(bpy) 3 2+ NPs were able to catalyze the reduction of coreactant H 2 O 2 of PEI-CdS QDs, while the PEI-CdS QDs could serve as the coreactant of TiO 2 -Ru(bpy) 3 2+ NPs, thus their ECL was promoted by each other. Additionally, graphene oxide (GO) was used to facilitate the electron transfer and sialic acid (SA) imprinted poly(3-aminophenylboronic acid) was electrodeposited on the resulting GO/TiO 2 -Ru(bpy) 3 2+ @PEI-CdS/GCE. When SA concentration increased the anodic ECL signal from TiO 2 -Ru(bpy) 3 2+ NPs increased, while the cathodic ECL signal from PEI-CdS QDs declined. The sensor exhibited high sensitivity, selectivity and stability. Under the optimized conditions, the linear range was 1.0 nM - 0.1 mM and the detection limit was low to 0.017 nM (S/N = 3). Its good practical feasibility was confirmed by detecting SA in real samples with satisfactory results.

研究领域: 分析化学 · 生物医学工程
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。