文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
PPG4000
ANALYTICA CHIMICA ACTA · 2021 · IF 6.558

Successive liquid-phase microextraction of acidic and basic analytes

Ruiqin Zhu,Hang Mei,Huajing Liu,Changbao Hong,Xiantao Shen,Chuixiu Huang

Practical biological and environmental samples always contain both acidic and basic substances, and the samples are always precious. Thus, separation of analytes with different nature from the same sample was of great significance. Successive liquid phase microextraction (sLPME) of acidic and basic analytes under optimal extraction conditions was therefore proposed for the first time. The concept of sLPME was proved by using three acidic analytes (naproxen, flurbiprofen and diclofenac) and three basic analytes (haloperidol, fluoxetine and sertraline) as model analytes, and using polypropylene glycol with an average molecular weight of 4000 (PPG4000) as SLM . The recoveries of all target analytes by sLPME were similar to that by individual LPME due to good affinity of PPG4000 to both acidic and basic analytes. Under optimal extraction conditions, the recoveries for all analytes by sLPME from urine samples were in the range of 62%–95%. Moreover, combined with LC-MS/MS, such sLPME approach was also evaluated with urine samples. The matrix effect of sLPME-LC-MS/MS at different levels for all analytes ranged from −14.1%–13.2%. The linear ranges with R 2  > 0.996 were 5–1000 ng mL −1 for basic analytes, and 20–1000 ng mL −1 for acidic analytes except diclofenac (1–1000 ng mL −1 ). The repeatability and accuracy at four levels were in the range of 3%–10% and 86%–120%, respectively. The limit of detection (LOD, S/N = 3) and limit of quantification (LOQ, S/N = 10) were found to be 0.07–0.49 ng mL −1 and 0.25–1.63 ng mL −1 , respectively. Finally, the strategy for constructing a sLPME system was further confirmed with urine, plasma and saliva using another two versatile SLM solvents possessing high affinity to both acidic and basic analytes. Successive LPME enabled separation of acidic and basic analytes from the same sample under optimum extraction conditions for all target analytes. Thus, we believe that the sLPME system will become a potent platform for forensic toxicology analysis, food science, environmental analysis and epidemiology study.

研究领域: 分析化学 · 环境科学 · 法医学毒理学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。