文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
PRMCECL
ANALYTICAL CHEMISTRY · 2020 · IF 6.785

Potential-Resolved Differential Electrochemiluminescence Immunosensor for Cardiac Troponin I Based on MOF-5-Wrapped CdS Quantum Dot Nanoluminophores

Dexin Du,Jiangnan Shu,Mingquan Guo,Mohammad A. Haghighatbin,Di Yang,Zhiping Bian,Hua Cui

Recently, nanoluminophores with the potential-resolved multicolor electrochemiluminescence (PRMCECL) property have emerged and shown promising applications in sensitive, selective, and accurate bioassays, bioimaging, and multicolor emitting devices. However, only limited PRMCECL nanoluminophores and their applications in ratiometric biosensors eliminating proportional errors have been reported. Herein, a novel PRMCECL nanoluminophore was synthesized by encapsulating CdS quantum dots (CdSQDs) into MOF-5 (CdSQDs@MOF-5). Using K2S2O8 as a coreactant, two electrochemiluminescence (ECL) peaks, ECL-1 centered at 685 nm and ECL-2 centered at 475 nm, were observed at −1.4 and −1.8 V, respectively. Related ECL mechanisms have been proposed. Based on the potential-resolved ECL signals, a label-free differential ECL immunosensor for the determination of cardiac troponin I (cTnI) was established by assembly of poly(diallyldimethylammonium chloride), CdSQDs@MOF-5, and cTnI antibody-functionalized silver nanoparticles on the surface of the fluorine-doped tin oxide electrode subsequently. In the presence of cTnI, cTnI was captured by the sensing interface, leading to an increase in ECL-1 and ECL-2 intensity. cTnI could be determined in the range of 0.01–1000 pg/mL with a detection limit of 5.01 fg/mL using the intensity difference between ECL-1 and ECL-2. This work provides a new family member of PRMCECL nanoluminophores. The proposed label-free differential ECL immunosensor provides a new strategy based on potential-resolved ECL signals, which could effectively eliminate the additive error and show better sensitivity, selectivity, and accuracy for the detection of cTnI than the single-signal strategy and ratiometric strategy.

CAS / MDL: 26062-79-3
研究领域: 电化学 · 纳米技术 · 生物传感器 · 心脏病学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。