文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
PSO算法
IEEE SENSORS JOURNAL · 2024 · IF 4.3

Construction of an ECL-DPV dual model biosensor for dopamine detection based on PSO-ANN algorithm

Zhikang Rao,Boyu Guo,Jixiang Zu,Weiqiang Zheng,Ying Xu,Yuting Yang

In clinical diagnosis, the detection of dopamine (DA) is often interfered by epinephrine (EP), a neurotransmitter drug that shares a similar structure with DA, which affects the accurate prediction of DA concentration. In this study, an electrochemiluminescence (ECL) and differential pulse voltammetry (DPV) dual model biosensor combined with machine learning algorithm was proposed for improving the selective detection of DA under EP interference. First, reduced graphene and gold nanoparticles were applied to enhance the sensitivity and stability of the sensor in ECL and DPV measurement. Compared with single model sensing, the dual model sensor could combine the superiority of ECL and DPV while improving the accuracy and reliability of experimental data. Then, nine graphic features related to concentration prediction were extracted from the ECL and DPV response curves, and Pearson’s correlation coefficient (PCC), as well as random forest (RF) algorithm, was adopted for feature importance analysis. To achieve accurate signal decoupling, an intelligent biologically inspired algorithm, particle swarm optimization (PSO) algorithm, was introduced to optimize initial weights and thresholds of the traditional artificial neural network (ANN) for further model training based on multi-feature fusion, which greatly increased the prediction accuracy of DA in the presence of EP. The results demonstrated that DA could be accurately predicted in the concentration range of 9– 200 μM , and the R2 between the true and predicted values of DA concentration reached 0.99. The root-mean-square error (RMSE) and mean absolute error (MAE) of the test dataset were 5.77 and 4.32 μM , respectively. In addition, the PSO-ANN-assisted ECL-DPV dual model detection scheme has been successfully applied for the determination of DA in real samples, such as goat serum and artificial urine.

研究领域: 生物医学工程 · 临床诊断 · 电化学传感
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。