文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
PU-CD
CHINESE JOURNAL OF POLYMER SCIENCE · 2025 · IF 4

Fluorescent Polyurea-Carbon Dots: Preparation, Characterization and Use as Sensor for Doxycycline Detection

Zhou Xiao-Xia,Yin Yi-Ting,Zhang Xiao-Yi,Li Shu-Sheng,Jiang Xu-Bao,Zhu Xiao-Li,Kong Xiang-Zheng

Fluorescent polyurea-carbon dots (PU-CD) were successfully achieved through a co-pyrolysis technique, combining polyurea (PU) with carboxyl-containing carbon dots (PCD) at a temperature of 220 °C. The PU was fabricated via a simple precipitation polymerization process using toluene diisocyanate in a water/acetone binary solvent system. PCD was generated by thermal treatment of poly(ethylene glycol) (PEG) at the same elevated temperature. To elucidate the structural characteristics of PU-CD, as well as its precursor components PU and PCD, a comprehensive suite of analytical techniques was employed, including transmission electron microscopy (TEM), Fourier transform infrared spectroscopy (FTIR), nuclear magnetic resonance (NMR), dynamic light scattering (DLS) and X-ray photoelectron spectroscopy (XPS). These analyses confirmed the formation of amide bonds resulting from the reaction between the terminal amines of PU and the carboxyl groups of PCD. An in-depth comparison of the fluorescence properties of PU-CD revealed marked enhancements in fluorescence intensity when contrasted with PU, PEG, and the individual PCD. The research explored the impact of various factors such as concentration, pH in aqueous solutions, and solvent type on the fluorescence emission of these materials, providing valuable insights into their emission mechanisms. It was particularly noteworthy that both PCD and PU-CD exhibited a confined-domain crosslink-enhanced emission effect. Utilizing the aqueous dispersion of PU-CD as a fluorescent probe, the detection of doxycycline (DOX), a long-acting, broad-spectrum, semi-synthetic tetracycline antibiotic, was achieved with a detection limit of 2.9×10 −7 mol/L. This study introduces a simple, green, and cost-effective fluorescent probe for the detection of DOX, which has significant potential for application in the realms of analytical chemistry and food safety monitoring in the future.

CAS / MDL: 67-68-5 564-25-0
研究领域: 分析化学 · 材料科学 · 纳米技术 · 传感器 · 环境监测
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。