文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

2 项

设置提升方向
PVC膜电极
MOLECULES · 2019 ·Vol. 24 ·期 3 ·420 · IF 3.06

An Enantioselective Potentiometric Sensor for 2-Amino-1-Butanol Based on Chiral Porous Organic Cage CC3-R

Bang-Jin Wang,Ai-Hong Duan,Jun-Hui Zhang,Sheng-Ming Xie,Qiu-E Cao,Li-Ming Yuan

Porous organic cages (POCs) have attracted extensive attention due to their unique structures and tremendous application potential in numerous areas. In this study, an enantioselective potentiometric sensor composed of a polyvinyl chloride (PVC) membrane electrode modified with CC3-R POC material was used for the recognition of enantiomers of 2-amino-1-butanol. After optimisation, the developed sensor exhibited enantioselectivity towardS-2-amino-1-butanol (logKS,RPot= −0.98) with acceptable sensitivity, and a near-Nernstian response of 25.8 ± 0.3 mV/decade within a pH range of 6.0–9.0.Keywords:enantioselective potentiometric sensor;2-amino-1-butanol;chiral porous organic cage;CC3-R;PVC membrane electrode

研究领域: 分析化学 · 材料科学 · 生物化学
✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
JOURNAL OF DISPERSION SCIENCE AND TECHNOLOGY · 2020 · IF 1.701

Potentiometric microsensor based on ion-imprinted polymer for the trace determination of cesium(I) ions

Long Wang,Zhiming Wang,Cuo Zhou,Weijun Song,Chunyan Sun

A cesium potentiometric microsensor based on magnetic ion-imprinted polymer (MIIP) has been developed for Cs(I) sensing. The core-shell structure Cs(I)-MIIP was synthesized by surface-imprinting technique, using functionalized magnetic Fe3O4@SiO2 microspheres, Cs(I) ion and carboxymethyl chitosan as supporter, template and functional monomers respectively. The resultant Cs(I)-MIIP was used as ionophore in the construction of the PVC membrane electrode to obtain a selective potentiometric microsensor toward Cs(I) ions. The fabricated sensor exhibited a highly sensitive Nernstian response (60.2 mV/decade) over the concentration range of 1 × 10−6 to 1 × 10−1 M of Cs(I). The response time of the microsensor was considerably short (less than 3 s) and its detection limit was determined as 3.0 × 10−7 M. The microsensor was effectively performed in the pH range of 4–6, and revealed desirable selectivity over a wide variety of other cations including alkali, alkaline earth and heavy metals. The proposed microsensor was also used for the determination of Cs(I) contents in the environmental water samples. The potentiometric results were in good harmony with the results obtained by the ICP-MS method.

研究领域: 分析化学 · 环境科学 · 材料科学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。