文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
R-1-氨基茚
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS · 2020 · IF 3.209

(S)-1-(5-(4-Methylpiperazin-1-yl)-2,4-dinitrophenyl)pyrrolidine-2-carboxylic acid as a derivatization reagent for ultrasensitive detection of amine enantiomers by HPLC-MS/MS and its application to the chiral metabolite analysis of (R)-1-aminoindan in saliva

Youxi Jin,Yu Pan,Biao Jin,Dongri Jin,Chunbo Zhang

(S)-1-(5-(4-Methylpiperazin-1-yl)-2,4-dinitrophenyl)pyrrolidine-2-carboxylic acid (Pro-PPZ) was employed as a chiral derivatization reagent (CDR) for the efficient enantioseparation and ultrasensitive mass spectrometric detection of chiral amines. Pro-PPZ was prepared from the one-step reaction of 1-(5-fluoro-2,4-dinitrophenyl)-4-methylpiperazine (PPZ) and l -proline. Two amines and two amino acid methyl esters were selected as model chiral amines, which were easily labeled with Pro-PPZ under mild reaction conditions (35 °C for 10 min) generating Pro-PPZ-amine derivatives. The resulting diastereomers were completely separated by reversed-phase liquid chromatography (RP-LC) using an ODS column ( R s = 3.4–17.0 for amines). Ultrasensitive detection limits on femtomolar level were obtained for the tested amines using multiple reaction monitoring (MRM) chromatograms at a single monitoring ion, m/z 289 (0.1–5.0 fmol for amines). The practical metabolite analysis of (R)-1-aminoindan (R-AI) in saliva samples was performed by LC–MS/MS using the Pro-PPZ derivatization method. The method was validated in terms of precision, accuracy, and linearity. Using this method, R-AI concentrations in saliva were determined after a single oral administration of the drug rasagiline to healthy male and female subjects, but no (S)-1-aminoindan (S-AI) was detected, which suggesting that R-AI was not converted into S-enantiomer in the metabolic process. R-AI concentrations in four healthy volunteers ranged from 32.85 nM to 49.45 nM, with an average value of 43.76 nM. To date, there is no LC–MS (or MS/MS) method reported for the enantioselective determination of R-AI in human saliva samples.

研究领域: 分析化学 · 药物代谢 · 临床医学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。