Developing instant detection systems with disease diagnostic capabilities holds immense importance for remote or resource-limited areas. However, the task of creating these systems—which are simultaneously easy to operate, rapid in detection, and cost-effective—remains a challenge. In this study, we present a compact highly sensitive photothermal reverse transcriptase–loop-mediated isothermal amplification (RT-LAMP) chip (SPRC) designed for the detection of multiple diseases. The nucleic acid (NA) amplification on the chip is achieved through LAMP driven by either LED illumination or simple sunlight focusing. SPRC performs sample addition and amplification within a limited volume and autonomous enrichment of NA during the sample addition process, achieving a limit of detection (LOD) as low as 0.2 copies per microliter. Through 120 clinical samples, we achieved an accuracy of 95%, with a specificity exceeding 97.5%. Overall, SPRC has achieved promising progress in the application of point-of-care testing (POCT) by using light energy to simultaneously detect multiple diseases.
Development of a simple, sensitive and specific method for HIV-1 assay is demanded. In some emergency situations, a portable reverse transcription loop-mediated isothermal amplification (RT-LAMP) platform is necessary. A novel hydrogen ion-selective RT-LAMP (H + -RT-LAMP) sensor was developed for highly sensitive HIV-1 using hydrogen ion concentration as a signal producing compound. The H + -RT-LAMP sensor was based on screen-printed with carbon-doped graphene conductive layer, carbon nanotubes (CNTs) solid electrolyte layer, and reference electrode KCl functional layer, which provided superior electrical signals, high sensitivity and stability for HIV-1 detection. The rate of hydrogen ion production was related to the viral load (VL) during the amplification of HIV-1. The sensitive HIV-1 RNA detection range was achieved from 0 copies/μL to 10 5 copies/μL. The proposed H + -RT-LAMP sensor was applied to detect HIV-1 RNA in real human serum. 57 samples were detected and satisfactory results were obtained. Compared with commercial instruments, the detection results of H + -RT-LAMP sensor demonstrated a perfect concordance rate of 96.5 %, and the limit of detection (LOD) for the clinical samples was 10 copies per tube. Time to get the result is from 10 min to 25 min. Therefore, the proposed H + -RT-LAMP sensor was particularly suitable as a point-of-care device for the on-site detection of HIV-1.