文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
Restylane
SCIENCE & JUSTICE · 2013 · IF 1.151

Systematical method for polyacrylamide and residual acrylamide detection in cosmetic surgery products and example application

Yuanfeng Wang,Ran Du,Tianshui Yu

Introduction In this paper, the authors presented a case of acrylamide poisoning in a middle-aged woman who had underwent unsuccessful cosmetic surgery six years earlier. The victim was told that the product that had been injected into her face was Restylane®, which mainly contained sodium hyaluronate and was the first and only Food and Drug Administration (FDA)-approved dermal filler for lip enhancement in the USA for more than 20   years. Widespread facial infections occurred several years post-injection; finally, the victim had to undergo removal surgery. Acrylamide poisoning was strongly suspected based on the victim's clinical manifestation. The product that had been injected into the victim's face was probably polyacrylamide hydrogel-based product, which had been prohibited by the State Food and Drug Administration (SFDA) in China in 2006. To confirm this suspicion, a systematical method was established to differentiate varieties of cosmetic surgery products and identify residential acrylamide. Methods The removed objects, original products and a certified reference sample of Restylane® were collected for examination. A direct microscopic examination was applied as a rapid screening method. Fourier transform infrared (FTIR) microspectroscopy analysis was subsequently performed to distinguish the main components from each sample. Automated solid phase extraction , ultra high performance liquid chromatography (SPE UHPLC) analysis was ultimately utilised and optimised to detect the residual acrylamide. Chromatographic separation was achieved on an ACQUITY UHPLC HSS T3 column. The mobile phase consisted of 0.01% aqueous formic acid solution and acetonitrile . The tunable UV (TUV) detection wavelength was at 202   nm. Results The microscopic examination indicated that different samples had different morphological characteristics , depending on their main components. The FTIR spectrum showed that different polymers could be distinguished according to the C O stretching vibration (1655   cm −   1 ), N H bending vibration (1540   cm −   1 ) and C O stretching vibration (1078 and 1045   cm −   1 ). The UHPLC results demonstrated that the calibration curve was linear in the range of 0.5–20.0   μg/mL, with a correlation coefficient of 0.999. The average recoveries of the method were 99–107% with an RSD of 1.6–6.3%. The detection limit was 0.1   μg/mL (S/N   =   3). The analytical time was 6   min per sample. Acrylamide was detected in the allegedly Restylane® injection. Conclusions This systematical method provides a rapid, accurate and sensitive determination of polyacrylamide and residual acrylamide. The microscopic and FTIR spectroscopic examinations help to verify the existence of polyacrylamide quickly and easily. The optimised SPE UHPLC-TUV method offers a simpler and more sensitive approach to confirm the amount of acrylamide, comparing to the methods in the literature.

CAS / MDL: 79-39-0
研究领域: 医学毒理学 · 分析化学 · 整形外科
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。