文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

3 项

设置提升方向
Ru@SiO2 纳米颗粒
ANALYTICAL CHEMISTRY · 2021 · IF 6.986

Light Scattering and Luminophore Enrichment-Enhanced Electrochemiluminescence by a 2D Porous Ru@SiO2 Nanoparticle Membrane and Its Application in Ultrasensitive Detection of Prostate-Specific Antigen

Chen Xu,Jing Li,Shimeles Addisu Kitte,Guohua Qi,Haijuan Li,Yongdong Jin

Electrochemiluminescence (ECL) by virtue of its controllability and versatility has emerged as a significant tool in bioassay, but how to integrate it with other (nano)materials and further break the limit of sensitivity for ultrasensitive detection still possess tremendous potential. Herein, a close-packed Ru@SiO2 NP nanomembrane that serves as an enhanced substrate and luminophore enricher simultaneously was constructed by the liquid–liquid interface self-assembly method and applied for ECL-enhanced bioassay. The developed ECL electrode obtained ∼600-fold enhancement on ECL intensity compared with the bare ITO electrode and ∼21-fold enhancement compared with the SiO2 NP nanomembrane electrode due to the dramatic light scattering of the 2D SiO2 NPs and the enrichment of Ru(bpy)32+ molecules on the surface of the Ru@SiO2 NP nanomembrane electrode. Based on the fascinating Ru@SiO2 NP nanomembrane platform, we further constructed a label-free immunosensor for the detection of prostate-specific antigen (PSA). The as-fabricated Ru@SiO2-nanomembrane ECL immunosensor exhibited good stability and performed ultrasensitive detection with an utmost low detection limit of 0.169 fg·mL–1 (signal/noise = 3). Our work puts forward an effective solution benefiting for further improving ECL performance for ultrasensitive bioassays.

研究领域: 生物医学工程 · 分析化学 · 纳米材料科学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
Chemosensors · 2024 ·Vol. 12 ·期 10 ·214 · IF 3.7

A Biomimetic Chip with Dendrimer-Encapsulated Platinum Nanoparticles for Enhanced Electrochemiluminescence Detection of Cardiac Troponin I

Yun Hui,Weijun Kong,Weiliang Shu,Zhiting Peng,Fengshan Shen,Mingyang Jiang,Zhen Xu,Tianzhun Wu,Wenhua Zhou,Xue-Feng Yu

The measurement of cardiac troponin I (cTnI) is of vital importance for the early diagnosis of acute myocardial infarction. In this study, an enhanced electrochemiluminescent immunoassay for the highly sensitive and precise determination of cTnI was reported. A biomimetic chip with nepenthes peristome surface microstructures to achieve single-layer microbead arrays and integrated microelectrode arrays (MEAs) for ECL detection was microfabricated. Ru@SiO2nanoparticles were prepared as signal amplificators labeling immunomagnetic beads. Dendrimer-encapsulated platinum nanoparticles (Pt DENs) were electrochemically modified on ITO MEAs. The resulting Pt DEN-modified ITO MEAs preserved good optical transparency and exhibited an approximately 20-fold ECL signal amplification compared to that obtained from bare ITO. The method made full use of the biomimetic chip with Pt DENs to develop single-layer immunomagnetic bead arrays with increasingly catalyzed electrochemical oxidation of the [Ru(bpy)3]2+–TPA system. Consequently, a limit of detection calculated as 0.38 pg/mL (S/N = 3) was obtained with excellent selectivity, demonstrating significant potential for the detection of cTnI in clinical diagnostics.

研究领域: 生物医学工程 · 分析化学 · 纳米技术 · 心脏病学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
Advanced Science · 2023 · IF 15.1

An Alternating Current Electroosmotic Flow-Based Ultrasensitive Electrochemiluminescence Microfluidic System for Ultrafast Monitoring, Detection of Proteins/miRNAs in Unprocessed Samples

Huiwen Xiong,Chenxin Zhu,Changhao Dai,Xin Ye,Yuanyuan Li,Pintao Li,Shuang Yang,Ghazala Ashraf,Dacheng Wei,Hui Chen,Huali Shen,Jilie Kong,Xueen Fang

Early diagnosis of acute diseases is restricted by the sensitivity and complex process of sample treatment. Here, an ultrasensitive, rapid, and portable electrochemiluminescence-microfluidic (ECL-M) system is described via sandwich-type immunoassay and surface plasmonic resonance (SPR) assay. Using a sandwich immunoreaction approach, the ECL-M system employs cardiac troponin-I antigen (cTnI) as a detection model with a Ru@SiO 2 NPs labeled antibody as the signal probe. For miR-499-5p detection, gold nanoparticles generate SPR effects to enhance Ru(bpy) 3 2+ ECL signals. The system based on alternating current (AC) electroosmotic flow achieves an LOD of 2 fg mL −1 for cTnI in 5 min and 10 aM for miRNAs in 10 min at room temperature. The point-of-care testing (POCT) device demonstrated 100% sensitivity and 98% specificity for cTnI detection in 123 clinical serum samples. For miR-499-5p, it exhibited 100% sensitivity and 97% specificity in 55 clinical serum samples. Continuous monitoring of these biomarkers in rats' saliva, urine, and interstitial fluid samples for 48 hours revealed observations rarely documented in biotic fluids. The ECL-M POCT device stands as a top-performing system for ECL analysis, offering immense potential for ultrasensitive, rapid, highly accurate, and facile detection and monitoring of acute diseases in POC settings.

研究领域: 分析化学 · 生物医学工程 · 医疗诊断 · 纳米技术 · 生物化学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。