文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

产品列表

视图 列表 网格

1 项目

设置提升方向
S. moorei
SENSORS AND ACTUATORS B-CHEMICAL · 2025 · IF 7.7

Screening and diagnosis of colorectal cancer using nucleic acid aptamers targeting Solobacterium moorei: Development of electrochemical sensors for clinical application

Decai Yuan,Cheng Qiu,Hui Chen,Feng Liu,Shanshan Feng,Peiyi Zhang,Ying Qin,Tingting Fan,Yan Chen,Yuyang Jiang

Colorectal cancer (CRC) represents a significant global health issue, necessitating innovative approaches for early screening and diagnosis. Recent advances in molecular diagnostics have highlighted the potential of aptamers for use as highly specific and sensitive probes for detecting cancer biomarkers. In this study, we focus on the identification of aptamers that selectively bind to Solobacterium moorei (S. moorei) , a bacterium associated with CRC. By integrating these aptamers into electrochemical sensor platforms, a reliable diagnostic tool is created for facile implementation in the clinical setting. More specifically, nucleic acid aptamers for S. moorei were obtained through whole-cell SELEX, and the affinity and specificity of these aptamers were validated. Subsequently, two types of electrochemical sensors were developed. Firstly, an electrochemical impedance spectroscopy sensor was developed to detect impedance changes on the electrode surface, which were caused by the binding of S. moorei to the aptamer. Secondly, a CRISPR/Cas12a-based electrochemical aptasensor was developed based on the ability of the Cas12a enzyme to be activated by specific single-stranded DNA, triggering its trans-cleavage activity. The limits of detection of these sensors for S. moorei were 30 and 6 CFU/mL, respectively. Clinical validation was performed using patient samples to assess the sensor efficacy in a real-world setting. The obtained results suggested that the abundance of S. moorei in the feces of CRC patients was significantly greater compared to that of healthy individuals. This integration of S. moorei aptamers into electrochemical sensors offers a non-invasive and cost-effective alternative to current screening methods available for CRC.

研究领域: 分子诊断学 · 生物传感技术 · 肿瘤学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。