文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
SMADC001
Journal of Pharmaceutical Analysis · 2021 · IF 4.769

Enzyme-linked immunosorbent assays for quantification of MMAE-conjugated ADCs and total antibodies in cynomolgus monkey sera

Min Pei,Tingting Liu,Lu Ouyang,Jianhua Sun,Xiaojie Deng,Xiaomin Sun,Wei Wu,Peng Huang,Yi-Li Chen,Xiaorong Tan,Xiaoyue Liu,Peng Zhu,Yongzhen Liu,Deheng Wang,Junliang Wu,Qi Wang,Guifeng Wang,Likun Gong,Qiuping Qin,Chunhe Wang

Antibody-drug conjugates (ADCs) are commonly heterogeneous and require extensive assessment of exposure-efficacy and exposure-safety relationships in preclinical and clinical studies. In this study, we report the generation of a monoclonal antibody against monomethyl auristatin E (MMAE) and the development, validation, and application of sensitive and high-throughput enzyme-linked immunosorbent assays (ELISA) to measure the concentrations of MMAE-conjugated ADCs and total antibodies (tAb, antibodies in ADC plus unconjugated antibodies) in cynomolgus monkey sera. These assays were successfully applied to in vitro plasma stability and pharmacokinetic (PK) studies of SMADC001, an MMAE-conjugated ADC against trophoblast cell surface antigen 2 (TROP-2). The plasma stability of SMADC001 was better than that of similar ADCs coupled with PEG4-Val-Cit, Lys (m-dPEG24)-Cit, and Val-Cit linkers. The developed ELISA methods for the calibration standards of ADC and tAb revealed a correlation between serum concentrations and the OD 450 values, with R 2 at 1.000, and the dynamic range was 0.3–35.0 ng/mL and 0.2–22.0 ng/mL, respectively; the intra- and inter-assay accuracy bias% ranged from −12.2% to −5.2%, precision ranged from −12.4% to −1.4%, and the relative standard deviation (RSD) was less than 6.6% and 8.7%, respectively. The total error was less than 20.4%. The development and validation steps of these two assays met the acceptance criteria for all addressed validation parameters, which suggested that these can be applied to quantify MMAE-conjugated ADCs, as well as in PK studies. Furthermore, these assays can be easily adopted for development of other similar immunoassays.

研究领域: 药理学 · 免疫学 · 生物化学 · 药物开发
✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。