文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

2 项

设置提升方向
SPE-LC-MS/MS
BIOMEDICAL CHROMATOGRAPHY · 2025 ·Vol. 39 ·期 2 ·e6067 · IF 1.7

Evaluation of the Impact of HIFU on Peptide Bond Formation: A Study Using SPE-LC-MS/MS Methodology

Jiale Liu,Rongfei Yuan,Qi Wang,Hai Qiao,Yuling Yang,Siyu Yang,Hua Zhang,Chang Chen

High-intensity focused ultrasound (HIFU) is a noninvasive soft tissue ablation technique, which utilizes ultrasound energy to induce thermal coagulation necrosis in targeted tissues. Whether this high energy causes side effects in vivo, such as the formation of peptide bonds, has not been fully investigated. Glycylglycine is the simplest dipeptide and hence is often used as a model compound for peptide studies. In this study, we developed and validated a sensitive quantification method based on ion-exchange solid-phase extraction, liquid chromatography, and tandem mass spectrometry (SPE-LC-MS/MS) for the analysis of glycylglycine without derivatization, and then used it to evaluate whether HIFU promoted peptide bond formation in aqueous solution (without enzymes) and plasma (with enzymes). The results showed that strong cation exchange SPE significantly reduced the matrix effect and improved the sensitivity of the LC-MS/MS method. No formation of glycylglycine in the aqueous solution or plasma was observed following HIFU irradiation.

CAS / MDL: 14091-11-3 103616-89-3
研究领域: 生物化学 · 医学工程
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
Journal of Environmental Sciences · 2024 · IF 5.9

Trace analysis of 59 halogenated aromatic disinfection byproducts through the SPE-LC-MS/MS method and their occurrence and transformation during chlorine disinfection

Shuang Chen,Yue Qiao,Youwei Jiang,Wei Qiu,Shuang Zang,Jing Zhang,Xianshi Wang,Jun Ma

Halogenated aromatic disinfection byproducts (DBPs) are gradually receiving attention due to their high detection frequency and usually higher toxicity than regulated DBPs. In this study, we established a solid phase extraction (SPE)-LC-MS/MS method to simultaneously trace analyze 59 halogenated aromatic DBPs. The limits of detection and limits of quantification of halogenated aromatic DBPs ranged from 0.03 ng/L to 135.23 ng/L and 0.1 ng/L to 450.76 ng/L, respectively. The range of recoveries and relative standard deviation (RSD) in river water were between 72.41 % to 119.54 % and 1.86 % to 16.03 %, respectively. Therefore, this method can be used to accurately analyze trace levels of halogenated aromatic DBPs in drinking water. The occurrence and transformation of halogenated aromatic DBPs were explored based on this method. In the chlorinated simulated source water and chlorinated river water, 20 and 45 halogenated aromatic DBPs were determined, respectively. The active halogen species (HOCl, HOBr, and HOI) first reacted with natural organic matter (NOM) to form halogenated aromatic DBPs. Then, chlorine further reacted with the halogenated aromatic DBPs to convert them into small-molecule halogenated aliphatic DBPs through oxidation, electrophilic substitution, and hydrolysis reaction, etc. In the chlorinated simulated source water, chlorinated river water, and tap water, the toxicity contribution of bromoacetic acids (Br-HAAs) accounted for the majority (> 71.16 %). Given that halogenated aromatic DBPs are intermediate products of halogenated aliphatic DBPs, controlling the formation of halogenated aromatic DBPs is beneficial in decreasing the formation of halogenated aliphatic DBPs, thereby diminishing the toxicity of drinking water.

CAS / MDL: 64-69-7 75-47-8
研究领域: 环境科学 · 分析化学 · 公共卫生
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。