文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
SPME-HPLC-UV
JOURNAL OF CHROMATOGRAPHY A · 2024 · IF 3.8

Ultrasound-assisted rapid growth of chemically bonded bifunctional mesoporous covalent organic framework submicrospheres on a nickel-chromium alloy support for efficient solid-phase microextraction of bisphenols from water and milk samples

Haixia Liu,Honghong Rao,Jinxin Guo,Baolan Lu,Yuyun Wang,Rongxi Zhu,Xinzhen Du

A layer-by-layer chemical bonding strategy was developed for fast in situ growth of bifunctional mesoporous covalent organic framework submicrospheres (COF SMSs) on the nickel-chromium alloy (Ni-Cr) fiber substrate via the ultrasound-assisted Schiff-base reaction for the first time. COF SMSs showed well-defined morphology, extraordinary high surface area (1211 m 2 · g −1 ) and narrow mesopore (2.50 nm) as well as excellent stability. Furthermore, the resulting Ni-Cr fiber presented outstanding adsorption capability and improved selectivity for bisphenols (BPs). Consequently, an attractive SPME-HPLC-UV approach with the Ni-Cr@Ni-Cr LDHs NSs@COF SMSs fiber was proposed for rapid preconcentration and sensitive determination of BPs. By optimizing adsorption parameters, the SPME-HPLC-UV method presented good linearity for five BPs in the ranges of 0.02–200 ng·mL −1 with coefficients of determination ( R 2 ) higher than 0.999. Limits of detection and limits of quantitation were obtained from 0.003 ng·mL −1 to 0.006 ng·mL −1 and from 0.010 to 0.019 ng·mL −1 , respectively. Moreover, the intra-day and inter-day precision expressed as relative standard deviations (RSDs) was 1.57–3.52 % and 2.65–4.38 % for the proposed method with a single fiber, respectively. RSDs of the proposed method with different duplicate fibers were 3.25–6.72 %. The proposed SPME-HPLC-UV method was available for efficient preconcentration and sensitive detection of five BPs from real water and milk samples. The relative recoveries at three spiking levels of BPs were achieved in the range of 80.00–118.8 % with RSDs below 7.81 %. In addition, the prepared fiber still exhibited satisfactory adsorption performance after 120 adsorption-desorption cycles.

研究领域: 分析化学 · 环境科学 · 材料科学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。