In this work, with the purpose of developing an effective and inexpensive method, excitation–emission matrix fluorescence data and second-order calibration method based on the self-weighted alternating trilinear decomposition (SWATLD) algorithm were combined for simultaneous determination of 2-naphthoxyacetic acid (NOA) and 1-naphthaleneacetic acid methyl ester (NAAME) in environmental samples, i.e. soil and sewage samples. In order to investigate the prediction quality of the proposed method, different strategies, such as taking spectroscopic measurements in the presence of different matrix interferents and at different fluorescence spectrophotometers, were introduced to build calibration models and comparisons among them were done subsequently. The root-mean-square error of prediction and t-test were used to compare different SWATLD-based calibration models. The limits of detection obtained for NOA and NAAME were 0.36–0.95 ng mL −1 and 1.32–2.69 ng mL −1 , respectively, for different models. Such a chemometrics-based protocol may possess great potential to be extended as a promising alternative for more practical applications in environment monitoring and for the design of small intelligent and field-portable analytical instruments that rely on statistical discrimination, not complete instrumental separation, of the target analytes even in the presence of unknown and uncalibrated interferences.
In this work, a simple and fast analytical method based on a self-weighted alternating trilinear decomposition (SWATLD) algorithm coupled with excitation–emission matrix (EEM) fluorescence was developed for the simultaneous determination of sulfamethoxazole (SMZ) and trimethoprim (TMP) illegally added to health products. With the second-order advantage, the proposed method obtained satisfactory results in the presence of peak overlap and unknown interferences. The analysis time for a single sample is only 0.8 minutes. The average spiked recoveries of SMZ and TMP in three health product spiked samples were in the range of 91.0–106.2% and 86.8–107.8%, respectively. The relative standard deviations (RSDs) were lower than 8.6%. In addition, verification parameters including sensitivity (SEN), selectivity (SEL), the limit of detection (LOD), the limit of quantification (LOQ), intra-day precision, and inter-day precision were calculated, and the results show that the proposed method is feasible. The quantitative results of the proposed method were further confirmed by the LC-MS/MS method, which proved that the proposed method was efficient and green for drug-abuse monitoring of SMZ and TMP in health products.