文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
Silicalite-1/PVA复合膜
SEPARATION AND PURIFICATION TECHNOLOGY · 2025 · IF 9

Boosting pervaporation separation of m-xylene from m/p-xylene isomers mixture through silicalite-1/PVA composite membrane

Wei Chen,Pengfei Wang,Weike Jia,Huidan Zeng

Silicalite-1 zeolites/polymer composite membranes are among the most reliable materials for the pervaporation separation of m-X from xylene isomers. However, the separation factors of the present silicalite-1 zeolites/polymer composite membrane are low. This work has succeeded in fabricating dense and defect-free silicalite-1/PVA composite membrane for first improving the pervaporation separation performance of m-X/p-X isomers. The silicalite-1/PVA composite membrane was prepared by combining solution scraping and vacuum thermal crosslinking methods with fumaric acid as a crosslinker (denoted as silicalite-1/PVA-V). The silicalite-1/PVA-V composite membrane with a thickness of 15.3 μm, prepared with a fumaric acid/monomeric unit of PVA molar ratio of 0.05 after vacuum thermal crosslinking at 160 ℃ for 2 h, exhibited dense and defect-free structure with extremely low xylene swelling degree, good structural stability and mechanical properties as well as excellent pervaporation separation performance. Compared to the pure PVA membrane, the silicalite-1/PVA-V composite membrane exhibited better selective separation performance of m-X isomer. The temperature, amount of fumaric acid, crosslinking degree and membrane thickness significantly influenced the pervaporation separation performance. The optimum selective separation factor of m-X/p-X isomers and the corresponding total permeate flux were about 9.85 and 59.15 g·m −2 ·h −1 (60 ℃), respectively. The pervaporation experiments of long-time and repetitively prepared membrane demonstrated that the silicalite-1/PVA-V composite membrane had long-term structural stability and reproducibility. To demonstrate scalability, we showed that our strategy could produce large-size silicalite-1/PVA-V composite membrane with an area of 1000 cm 2 , which exhibited m-X separation performance similar to that of small membrane coupons. The present work provided a potentially scalable method for producing high-quality silicalite-1/PVA composite membrane for enhancing the pervaporation separation performance of m-X from xylene isomers.

研究领域: 材料科学 · 化学工程
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。