文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
TA/CB@PDMS
MEASUREMENT SCIENCE and TECHNOLOGY · 2024 ·Vol. 35 ·期 4 ·045109 · IF 2.7

Design of flexible sensor for wind pressure monitoring of stay cables

Xiaoming Wang,Zhilong Guo,Yifeng Huang,Longbo Xiong,Daojin Yao,Wentao Dong

Strong winds can make a bridge's cable-stayed cables produce violent vibrations, leading to fatigue of the cable-stayed cables and damaging the cable-stayed bridge's structure. Accurately and effectively obtaining data on the wind loads applied to the cable-stayed cables is important for assessing the cable-stayed cables' health. The existing sensing elements for detection include diffusion silicon piezoresistive sensor, strain gauge, and other rigid sensors. However, most of them present such disadvantages as rigidity, difficult to fit the curved surface, high cost and low sensitivity. And it cannot be directly installed on the surface of the cable. In this paper, a conductive hydrogel flexible pressure sensor based on TA/CB@PDMS was developed, using carbon black (CB) as the main conductive medium, with good electrical conductivity, high sensitivity (0.65 kPa−1) and excellent tensile properties (210% tensile breakage). Meanwhile, a salt permeation method (Soak the sensor in LiBr solution) was used to effectively inhibit the sensor's water from being evaporated and frozen. Its substrate incorporates tannic acid to increase the sensor's adhesion so that it adheres well to the diagonal cable's surface. In this paper, the wind speed variation around the diagonal cable and the force distribution on the surface with considering the fluid-structure coupling effect are analyzed by ANSYS WORKBECH finite element simulation. Wind tunnel experiments simulate the sensor's force response when the inclined cable is subjected to different wind speeds, and the detection accuracy reaches 96.17%. The results show the sensor developed in this paper can realize accurate wind pressure detection of the inclined cable. This study provides a new method for wind pressure detection and health inspection of diagonal cables.

研究领域: 土木工程 · 材料科学 · 传感技术 · 结构健康监测
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。