文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
TMB探针
BIOELECTROCHEMISTRY · 2025 · IF 4.5

A colorimetric/electrochemical dual-mode aptasensor for Golgi protein 73 detection using TMB as a bifunctional probe

Guiyin Li,Jing Su,Min Chen,Xiaohong Tan,Lingling Fan,Zhide Zhou,Chong Hu,Jintao Liang

Golgi protein 73 (GP73) has emerged as a critical biomarker for the diagnosis of hepatocellular carcinoma (HCC), and its detection is essential for the effective treatment of this disease. In this study, we developed a colorimetric/electrochemical dual-mode aptasensor for GP73 detection using a hemin-reduced graphene oxide‑manganese oxide (H-rGO-Mn 3 O 4 ) nanozyme and the bifunctional probe, 3,3′,5,5′-tetramethylbenzidine (TMB). The GP73-specific aptamer (Apt) was conjugated to the H-rGO-Mn 3 O 4 nanozyme, which was then immobilized on the surface of a gold nanoparticle-modified screen-printed electrode (Au NPs/SPE) through hybridization with a complementary DNA strand (cDNA) attached to the electrode. TMB served as a dual-signal probe for both colorimetric and electrochemical detection. In the presence of GP73, Apt binds specifically to the target, forming a H-rGO-Mn 3 O 4 -Apt/GP73 complex structure. This binding event causes the nanozymes to detach from the electrode surface, reducing its peroxidase activity while simultaneously restoring the electrochemical signal. Under optimized conditions, the dual-mode aptasensor exhibited excellent linear responses for GP73 concentrations ranging from 0.0001 to 100 ng/mL, with limits of detection (LOD) of 0.1 pg/mL for both the colorimetric and electrochemical modes. The aptasensor was successfully applied to measure GP73 levels in serum samples, yielding highly consistent results. Its performance was further validated by comparison with the standard ELISA method. Compared to single-signal aptasensors, this dual-mode approach not only improves detection sensitivity but also minimizes the risk of false positives or false negatives, making it a more reliable tool for accurate GP73 detection in clinical diagnostics.

研究领域: 肿瘤学 · 分子诊断 · 生物传感器 · 纳米医学 · 临床检验 · 转化医学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。