文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
TUBB3
ACS Applied Materials & Interfaces · 2025 · IF 8.2

TUBB3/DTX LNPs Dry Powder Inhaler and an Efficient Delivery Device for Targeted Therapy of Lung Cancer

Mingyuan Li,Xianglong Wang,Mengsi Yin,Faxin Zhang,Wenlin Ma,Linze Che,Jinhao Yu,Yan Cheng,Mengju Xu,Xiaofu Liang,Wen Su,Hongmeng Ren,Weixue Si,Jingsi Ma,Shaodan Peng,Xiaolong Zhao,Jiaping Zhou,Ziqi Wu,Jiang Deng,Hua Sun

Lung cancer is the most prevalent and deadly tumor globally, marked by drug resistance and a poor prognosis. Specialized formulations with strong lung targeting are currently lacking. Docetaxel (DTX) and TUBB3-siRNA represent chemotherapy and RNA interference (RNAi), two strategies for lung cancer treatment. Lipid nanoparticles (LNPs) are nanocarriers suitable for nucleic acid delivery. In this study, spray freeze-drying (SFD) converted LNP colloidal solutions into inhalable dry powders. Fresh and rehydrated LNP (SFD) showed sizes below 200 nm, ζ potentials near 0 mV, and uniform roundness by transmission electron microscopy. The geometric particle size distribution (D50) of TUBB3-LNPs, DTX-LNPs, and TUBB3/DTX-LNPs inhalable powders did not differ significantly (1.99–5.90 μm). The median mass aerodynamic diameter (MMAD) was 2.61 ± 0.32 μm, suitable for pulmonary deposition. Experiments with BEAS-2B and H460 cells showed that TUBB3/DTX-LNPs had low cytotoxicity and good biocompatibility with BEAS-2B but strongly inhibited H460 cells. Differences in apoptosis induced by fresh LNPs and rehydrated LNP (SFD) indicate that the SFD process preserves normal cell viability while maintaining tumor inhibition. Because dry powder inhalers combine the drug formulation with the delivery device, a specialized single-dose prefilled device was developed that featured four symmetrically configured orifices (vents) located in the middle of the tube body; it achieved a high dry powder emptying rate of 95–100%. Furthermore, this study demonstrated the lung-targeting efficacy and sustained-release properties of the formulation.

CAS / MDL: 38215-36-0
研究领域: 药剂学 · 纳米技术 · 肿瘤学 · 药物递送 · 呼吸医学 · 生物化学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。