文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
UV/Air工艺
WATER RESEARCH · 2019 · IF 7.913

Low-Fe(III) driven UV/Air process for enhanced recovery of heavy metals from EDTA complexed system

Yuan Yuan,Wei Zhao,Zicheng Liu,Chen Ling,Changqing Zhu,Fuqiang Liu,Aimin Li

The efficient recovery of heavy metals from complexed wastewater is an essential but challenging task. In this study, a novel low-Fe(III) driven UV/Air process (LFUA) was developed to break the strong complexation between ethylenediamine tetracetic acid (EDTA) and heavy metal ions (HMIs) and enable the enhanced recovery of HMIs via chelating resin adsorption (CRA). The inside mechanism of the LFUA process includes: 1) displacement of HMIs from HMI-EDTA complexes by Fe(III); 2) direct photolysis of Fe(III)-EDTA through a ligand-to-metal charge transition reaction (LMCT) and indirect photolysis of EDTA by HO 2 ·/O 2 · - . The iron dosage was orders of magnitude lower than that previously reported, due to the Fe(II)/Fe(III) redox cycle in the LFUA process. Fe(II) formed during the LMCT reaction of Fe(III)-EDTA was oxidized back to Fe(III) by O 2 and HO 2 ·, and the reformed Fe(III) was then recombined with EDTA to sustains the LMCT reaction. EDTA was completely removed in 20 min at a molar ratio of Fe(III)/EDTA = 0.05. In addition, following the LFUA process, the adsorption amounts of various HMIs onto D463 resin were at least two orders of magnitude higher than those reported using the direct adsorption process. Employing the integrated technique of LFUA + CRA enabled the efficient removal of up to 64.5 mg/L of Cu(II) from inlet wastewater, and residual Cu(II) was below 0.5 mg/L. The results of desorption experiments showed that over 90% of Cu(II) was recovered, and the desorption solution had a Cu concentration of 2.1 g/L and purity of 99%. Furthermore, the economic and practical feasibility of using the combined process of LFUA + CRA was analyzed to substantiate that the technique is highly efficient and clean (produces no harmful sludge). Therefore, it is an appropriate and practical process in removing HMIs-EDTA complexes and recovering HMIs from wastewater.

研究领域: 环境科学 · 化学工程
✓ 已验证 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。