文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
UiO-66-NH2@Ru
MICROCHEMICAL JOURNAL · 2020 · IF 3.594

Ratiometric fluorescence detection of melamine in milk by a zirconium-based metal-organic frameworks composite

Chunhua Lin,Caijun Zhong,Yonghai Song,Li Wang

Melamine has biological toxicity and is forbidden to be used in food processing and food additives. The long-term ingestion of melamine will cause renal malfunction and metabolic problems of the urinary system, so it is of great significance for the rapid and selective detection of melamine. Herein, a zirconium-based metal–organic frameworks (Zr-based MOFs) encapsulated tris(2,2-bipyridyl)ruthenium (II) chloride hexahydrate ([Ru(bpy) 3 ] 2+ ) composite, donated as UiO-66-NH 2 @Ru, was reported and further studied its sensing performance for melamine based on ratiometric fluorescent method. The UiO-66-NH 2 @Ru was prepared from ZrCl 4 , 2-amino-terephthalic acid (TPA-NH 2 ) and [Ru(bpy) 3 ] 2+ by one pot reaction through solvothermal method, which exhibited dual emission signals at 445 and 595 nm from single excitation of 350 nm. The corresponding two peaks showed different responses to melamine, that was, the obvious enhancement at 445 nm and the slow decrease at 595 nm, thus achieving the “on–off” ratiometric fluorescence detection. When the concentration of melamine was in the range of 0.27 to 110 μM, the ratio of fluorescence intensity F 445 /F 595 had a good linear relation with the correlation coefficient R 2  = 0.995 and the detection limit of 90 nM. The synthetic UiO-66-NH 2 @Ru probe implemented rapid determination of melamine in real sample of milk powder with high sensitivity and selectivity. Compared with the reported carbon dots, quantum dots, metal nanoclusters, nanocomposites and other fluorescent sensors, MOFs-based sensor have broadened the application of nanomaterials in melamine detection for the first time. This study also demonstrates the Zr-based MOFs as a platform to encapsulate fluorescent dye for constructing ratiometric sensor in the determination of melamine is feasible and exciting.

CAS / MDL: 10312-55-7 108-78-1
研究领域: 食品安全检测 · 纳米材料科学 · 分析化学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。