Chenglong Guo,Jiacong Xiao,Jianchun Zeng,Youjun Zeng,Yi Liu
Surface Plasmon Resonance imaging (SPRi) is a powerful label-free technique for high-throughput biochemical analysis. Wavelength modulation is particularly suitable for SPRi due to its wide dynamic range and robustness to fabrication tolerances. However, conventional systems relying on tunable filters (e.g., AOTF, LCTF) suffer from high cost, complexity, and limited temporal resolution. To overcome these drawbacks, we developed a rapid wavelength-modulation SPRi system using a multi-LED source and an adaptive second-order fitting (ASF) algorithm. The system covers the 730–805 nm spectrum with five LEDs. The ASF algorithm first performs a coarse full-spectrum scan to locate the resonance wavelength, then dynamically selects an optimal three-LED subset for fast second-order fitting, enabling accurate reconstruction of resonance wavelength without mechanical scanning. This approach significantly reduces cost and complexity while achieving a scanning cycle of 105 ms, RI resolution of 5.54 × 10−6RIU, dynamic range of 0.0241 RIU, and excellent multi-channel consistency. The system has been successfully applied to monitor multi-channel antibody–antigen interactions in real time. Furthermore, it was used to detect cartilage oligomeric matrix protein (COMP) in synovial fluid, where an elevated concentration in an osteoarthritis sample versus a control aligned with its role as a cartilage catabolism marker. This work validates a practical and reliable platform for early diagnosis of osteoarthritis.
Wavelength interrogation surface plasmon resonance imaging (WSPRi) sensing has unique advantages in high-throughput imaging detection. The refractive index resolution (RIR) of WSPRi is limited to the order of 10 −6 RIU. This paper demonstrates a novel WSPRi sensing system with a wavelength scanning device of an acousto-optic tunable filter (AOTF) and a low-cost speckle-free SPR excitation source of a halogen lamp. We developed a sensitive quasi-phase extraction method for data processing. The new technique achieved an RIR of 8.84×10 −7 RIU, which is the first WSPRi system that has an RIR in the order of 10 −7 RIU. Moreover, we performed a real-time recording of the formation of the coffee ring effect during brine evaporation and enhanced the biosensor performance of SPR for the first time. We believe the higher RIR and accuracy of the system will benefit more potential applications toward exploring the biomolecules’ behaviors in biological and biochemistry studies. Graphical abstract