文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

347,358+ SCI 论文 与阿拉丁产品引用相关
2,303,472.95 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

产品列表

视图 列表 网格

3 项

设置提升方向
X射线辐照
JOURNAL OF RARE EARTHS · 2024 · IF 5.2

Deeply trapped electrons induced long-time sustainable mechanoluminescence of X-ray irradiated La2Ti2O7:Pr3+ for detection of stress burst

Chunqing Fu,Wei Meng,Xiaoyan Fu,Shuya Wang,Wenzhi Sun,Hongwu Zhang

X-ray irradiated La 2 Ti 2 O 7 :Pr 3+ was found to show long-time sustainable mechanoluminescence (ML), which can realize the high sensitivity and real time detection of stress burst for more than 72 h. Under the excitation of X-ray, La 2 Ti 2 O 7 :Pr 3+ shows red ML emissions located at 610, 624 and 638 nm, which are similar to the afterglow emission spectrum and can be ascribed to 1 D 2 - 3 H 4 , 3 P 0 - 3 H 4 and 3 P 0 - 3 H 2 of Pr 3+ . And the linear increases of compressive load can induce the linear increases of ML intensity of the sample, indicating that the X-ray induced ML emission can be utilized to accurately detect the stress applied on the object. Furthermore, X-ray irradiated La 2 Ti 2 O 7 :Pr 3+ possesses excellent stability and the repeatability of ML emission and the ML signals can keep stable even 50 load cycles after 1 h decay. The thermoluminescence results suggest that abundant electrons are trapped in shallow and deep answered for stable ML emission. More importantly, the deeply trapped electrons induced ML emissions from X-ray irradiated La 2 Ti 2 O 7 :Pr 3+ can be utilized to detect the stress bursts for a long time. When the sample is recharged by 5 min X-ray irradiation once, within 24 h decay, the 1500 N burst among many 1000 N cycles can be clearly detected, and the signal to noise ratio (S/N) reaches 1.32 and 1.26 after 12 and 24 h decay, respectively. And even after 72 h decay, the S/N of 2500 N still arrives at 1.23 and that of 4000 N reaches 1.97, indicative of long-time high sensitivity detection of abnormal stress. All these results suggest that the X-ray-irradiated La 1.97 Ti 2 O 7 :0.03Pr 3+ /resin sample can realize the high sensitivity and real time detection of stress burst for more than 72 h, which thus possesses great potential application in early warning of the emergency disasters such as bridge fracture, tunnel collapse and so on.

研究领域: 材料科学 · 光学 · 物理学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
LWT-FOOD SCIENCE AND TECHNOLOGY · 2024 · IF 6

Differentiation of Electron Beam and X-ray Irradiation Modified Starch under Vacuum Conditions: Multi-scale Structure and Properties

Danyang Liang,Lin Luo,Haiyu Luo,Qing Liu,Khamiddolov Temirlan,Wenhao Li,Wenjie Yan

This study modified lentil starch stored in a vacuum and regular (Ziplock-packed) conditions using electron beam irradiation and X-rays. The effects of these irradiations and environments on starch modification were evaluated by comparing changes in physicochemical and functional properties. Both electron beam and X-ray irradiation significantly reduced the short-range order and molecular weight of the starch while increasing the content of short chains. Under a vacuum environment, all irradiations exhibited more substantial degradation effects than regular conditions. Electron beam irradiation significantly reduced the relative crystallinity and the content of long chains, whereas X-rays had a more pronounced impact on disrupting the crystal structure of lentil starch. The vacuum environment enhanced the effectiveness of irradiation in improving the antidigestive properties of starch, leading to an increase in resistant starch content from 75.75% to 79.22%. This study offers new insights into producing modified starches using irradiation in combination with specific treatment environments.

研究领域: 食品科学 · 分子生物学
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
Advanced Optical Materials · 2023 ·Vol. 12 ·期 11 ·2302434 · IF 9

Organic–Inorganic Hybrid Mn-Based Transparent Glass for Curved X-Ray Scintillation Imaging

Zhi-Zhong Zhang,Zi-Lin He,Jian-Bin Luo,Jun-Hua Wei,Xiu-Xian Guo,Jing-Hua Chen,Dai-Bin Kuang

The current mainstream planar X-ray imaging techniques face significant challenges for accurately capturing the internal structure of curved objects, since the variable distances between the curved objects and the flat-panel scintillation screen cannot eliminate the distortion in X-ray imaging. Though large-area and transparent curved scintillation screens are much more desirable. Here, organic–inorganic hybrid Mn-based single crystals ([CH 3 Ph 3 P] 2 MnX 4 , X = Cl, Br, I) exhibiting high photoluminescence quantum yield (PLQY) and low melting temperature have been employed to prepare transparent glass for X-ray scintillation imaging application through a low-temperature melting strategy. The [CH 3 Ph 3 P] 2 MnBr 4 -glass shows high PLQY (47.8%), high-resolution X-ray imaging performance (12.3 lp mm −1 ), low limit of detection (25.33 nGy s −1 ), and impressive X-ray irradiation stability (102 Gy). Furthermore, high-contrast X-ray imaging at a low dose (6.865 µGy per exposure, 14.5 times lower than the chest radiograph) is achieved. Based on the low glass transition temperature ( T g = 53.6 °C) and easy-shapeable properties of [CH 3 Ph 3 P] 2 MnBr 4 -glass scintillator, the large-area curved scintillation screen with a series of sizes of Φ 2×4 – Φ 8×4 cm 2 can be easily fabricated and show high X-ray imaging quality. These findings provide a paradigm for future research in shapeable X-ray scintillators, unlocking new possibilities for curved and 3D X-ray imaging.

研究领域: 材料科学 · 光学 · 放射学 · 成像技术
✓ 已验证 DOI 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。