文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

2 项

设置提升方向
Zn2 检测
TETRAHEDRON LETTERS · 2016 · IF 2.347

Conjugated oligomers with thiophene and indole moieties: Synthesis, photoluminescence and electrochromic performances

Ben Dong,Baoyan Li,Yi Cao,Xinlei Meng,Han Yan,Shusheng Ge,Yun Lu

Two series of thiophene oligomers and terthiophene oligomers consisting of both thiophene and indole moieties have been synthesized. They have same excitation-dependent photoluminescence characteristics, but different bandgaps and absorption behaviors, which relates to the number and denseness of indoles in the conjugated oligomers and the length of alkyl chains on indole moiety due to varied the π-π stacking interaction of conjugated structures in the as-prepared oligomers. A simple electrochromic device based on such a conjugated oligomer displays a novel four-color electrochromism from red to yellow, green and puce with the increased potential and possesses good environmental and redox stability. Such conjugated oligomer also exhibits high sensitivity and selectivity for Zn 2+ detection.

研究领域: 材料科学 · 光电化学
✓ 已验证 产品关联 DOI 高影响因子
查看原文 查看 PubMed
JOURNAL OF COLLOID AND INTERFACE SCIENCE · 2018 · IF 5.091

“On-off-on” fluorescent system for detection of Zn2+ in biological samples using quantum dots-carbon dots ratiometric nanosensor

Quan Song,Yunsu Ma,Xu Wang,Tang Tang,Yueyue Song,Yujie Ma,Guanhong Xu,Fangdi Wei,Yao Cen,Qin Hu

In this work, a novel strategy for Zn 2+ detection was established by using an “on-off-on” ratiometric fluorescent nanosensor with the help of ethylene diaminetetraacetic acid (EDTA), a common metal chelating agent. The simple and practical ratiometric fluorescent nanosensor was synthesized by covalently binding CdTe quantum dots (QDs) and carbon dots (CDs), possessing two emission peaks at 525 nm and 450 nm under a single wavelength excitation of 360 nm, respectively. The CdTe QDs served as the response signal label, and the CDs, having no response to the analytes, acted as the reference signal. The fluorescence emission of the nanosensor was turned off to create a low-level “off” state when EDTA was added, and turned on dramatically with the addition of the target Zn 2+ . Under the optimal conditions, the change of the fluorescence intensity ratio of the nanosensor at 525 nm and 450 nm (ΔF 525 /F 450 ) had good linearity against the concentrations of Zn 2+ within a dynamic linear range of 0.50–40 μM. The limit of detection was as low as 0.33 μM (3σ/K), which was low enough for the detection of Zn 2+ in human body. The proposed method was successfully applied to the detection of Zn 2+ in human urine and plasma with RSDs less than 10%. The results show that the as-prepared QDs-CDs ratiometric nanosensor has potential application of clinical detection of Zn 2+ in the human body.

CAS / MDL: 25952-53-8 6066-82-6
研究领域: 分析化学 · 纳米技术 · 生物医学工程
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。