文献检索

查找使用阿拉丁产品的科研文献

检索与阿拉丁产品相关的同行评审论文、DOI、PubMed 编号、期刊、作者、CAS 号及研究领域。

科研影响力快照

与阿拉丁产品相关的已发表科研成果

在搜索之前,这些指标可帮助访客快速了解产品关联科研的规模与质量。

346,364+ SCI 论文 与阿拉丁产品引用相关
2,295,288.15 总影响因子 匹配文献记录中影响因子的总和
81.20 最高期刊影响因子 匹配期刊中的最高 IF
6.63 平均期刊影响因子 匹配文献的平均 IF

参考指标 指标基于阿拉丁文献引用数据库及期刊影响因子记录。文献关联仅供科研参考,请以原始文献为准。

热门产品

视图 列表 网格

1 项目

设置提升方向
pH测定
CHEMOSPHERE · 2019 · IF 5.108

Direct measurement of aerosol pH in individual malonic acid and citric acid droplets under different relative humidity conditions via Raman spectroscopy

Pianpian Chang,Zhe Chen,Yunhong Zhang,Yong Liu

Acidity of aerosol particles plays important roles in atmospheric chemistry , in turn, impacting climate system and public health. Current knowledge of acidity in atmosphere aerosols remains fairly scarce largely because of difficulty in direct measurement. On the other hand, indirect methods for estimating aerosol pH are often inconsistent with pH values predicted by thermodynamic models. Recently, a direct Raman spectroscopy method has been reported to determine pH values of acid-conjugate base equilibria systems based on Raman intensity of distinct characteristic peaks of conjugate acid-base pair. Nevertheless, for pure carboxylic acid aerosol particles, such as malonic acid (MA), characteristic peak of its conjugate base cannot be clearly observed in Raman spectra owing to small K a value (weak acid dissociation constant), which leads to little dissociation of weak acid and low concentration of its conjugated base. As a result, pH of carboxylic acid particles cannot be directly determined by calibrating concentrations of acid and its conjugated base using the above-mentioned method. To address such an issue, we demonstrate a new approach for determining pH values of malonic acid (MA) and citric acid (CA) droplets under different relative humidity (RH) based on calibration curves. We measure Raman intensity ratios of acid solutions at different concentrations and their pH values to establish a calibration curve, and then using the intensity ratio of MA and CA droplets under different RH to determine aerosol particle pH based on calibration curves. Results have shown that aerosol pH of MA droplet decreases with a decreasing RH and pH values ranges from 1.03 to −0.12, when RH value is reduced from 90% to 26%, in good agreement with model prediction values. In addition, we also, for the first time, report pH values of CA droplets under different RH conditions and its pH values range from 1.13 to −0.74 when RH is reduced from 91% to 28%.

CAS / MDL: 77-92-9 5949-29-1
研究领域: 大气化学 · 环境科学 · 分析化学
✓ 已验证 产品关联 DOI PubMed 高影响因子
查看原文 查看 PubMed
已复制

文献关联基于可获得的产品、CAS、DOI 及引用记录。收录不代表作者或出版方对阿拉丁产品的背书,请以原始文献为准。