常见问题(FAQs)

RT-LAMP Isothermal Amplification Kit (Lyophilized) FAQ

RT-LAMP Isothermal Amplification Kit (with Fluorescent Dye, Lyophilized) is a ready-to-use, lyophilized one-step reagent system that enables rapid, sensitive, and specific reverse-transcription loop-mediated isothermal amplification of RNA targets at a constant temperature, with real-time fluorescent readout requiring no thermal cycler.

Product SKU
R1547530
Kit Format
Lyophilized (freeze-dried), single-tube or multi-well format for extended shelf life and ambient shipping
Detection Method
Fluorescent dye-based real-time monitoring; positive signal observed as increase in fluorescence intensity
Amplification Principle
Loop-mediated isothermal amplification (LAMP) coupled with reverse transcription (RT) for RNA targets; reactions proceed at a single constant temperature (typically 60–65 °C)
Key Advantage
No thermal cycler required; lyophilized format provides stability, ease of transport, and simplified workflow
Intended Use
Research use only (RUO); suitable for detection of RNA viruses, gene expression studies, and point-of-need nucleic acid testing

What Is RT-LAMP and How Does the Kit Work?

Loop-mediated isothermal amplification (LAMP) is a nucleic acid amplification method that uses a strand-displacing DNA polymerase and a set of four to six specially designed primers to amplify a target sequence with high specificity under isothermal conditions, eliminating the need for a thermal cycler. When coupled with reverse transcription (RT), the technique can directly amplify RNA targets, including viral genomes and messenger RNAs.

The RT-LAMP Isothermal Amplification Kit (with Fluorescent Dye, Lyophilized) integrates a reverse transcriptase and a strand-displacing polymerase into a single lyophilized reaction pellet. Upon rehydration with the sample and buffer, the enzyme mix converts the RNA template into cDNA and immediately initiates LAMP amplification. A fluorescent intercalating or sequence-specific dye included in the formulation produces an increasing fluorescence signal as amplification products accumulate, enabling real-time monitoring with a compatible fluorescence reader or simple visual inspection under UV light.

The lyophilized format stabilises all enzymatic and chemical components at room temperature, reducing cold-chain dependence during shipping and storage.

Storage, Stability, and Handling

Lyophilized Kit Storage: Store the lyophilized reagent according to the conditions specified on the product label and Certificate of Analysis. The lyophilized format is designed for improved thermal stability; however, the recommended storage temperature should be followed to ensure optimal performance over the stated shelf life. Consult the product documentation for specific temperature requirements.

After Rehydration: Once rehydrated, the master mix should be used promptly. Avoid repeated freeze-thaw cycles of the rehydrated material, as this can reduce enzyme activity. If the rehydrated mix cannot be used immediately, store on ice and use within the timeframe specified in the protocol.

RNA Sample Handling: RNA is highly susceptible to degradation by RNases. All work with RNA should be performed using RNase-free consumables, water, and surfaces. Wear gloves at all times and change them frequently to prevent RNase contamination from skin.

Contamination Prevention: LAMP amplification produces very large amounts of amplicon. To prevent carryover contamination, maintain strict physical separation between pre- and post-amplification areas, and use aerosol-barrier pipette tips throughout.

Troubleshooting Common Issues

No Signal in Positive Control: Verify that the reaction temperature is accurate and stable. Check that the correct volume of rehydration buffer was used and that the pellet was fully dissolved. Confirm that primers were added at appropriate concentrations and that the RNA positive control is intact and undegraded.

Signal in No-Template Control (False Positive): LAMP is prone to non-specific amplification and aerosol contamination due to its high sensitivity. Ensure strict separation of pre- and post-amplification areas. Use fresh, RNase-free water for rehydration. Redesign primers if non-specific amplification persists.

Weak or Delayed Signal: Optimise primer concentrations (typically FIP and BIP at higher concentrations than outer primers). Ensure RNA input is within the recommended range and of sufficient quality. Suboptimal incubation temperature or inhibitors in the RNA extract may reduce efficiency.

Inconsistent Results Between Replicates: Ensure thorough mixing after rehydration and primer addition. Pipette carefully to avoid introducing air bubbles. Use a calibrated heat block or water bath with uniform temperature distribution.

Ordering, Compliance, and Support

How to Order: The RT-LAMP Isothermal Amplification Kit (with Fluorescent Dye, Lyophilized) is available from Aladdin Scientific under SKU R1547530. Orders can be placed through the Aladdin Scientific website, by contacting your local sales representative, or via institutional procurement channels. Please confirm pack size and quantity requirements at the time of ordering.

Regulatory Status: This product is intended for research use only (RUO) and is not approved, cleared, or licensed for diagnostic, therapeutic, or clinical use. Users are responsible for validating the product for their specific application in accordance with applicable regulations.

Technical Support: For application-specific guidance, protocol optimisation advice, or troubleshooting assistance, please contact Aladdin Scientific technical support. Provide the product SKU, lot number, a description of your experimental setup, and the issue observed to facilitate a prompt response.

Safety Data Sheet (SDS): An SDS for this product is available on the Aladdin Scientific website and can be requested from customer service. Review the SDS before use and follow all applicable laboratory safety regulations when handling reagents.

Frequently asked questions

Does the kit include RT-LAMP primers for a specific target?

No, the RT-LAMP Isothermal Amplification Kit (with Fluorescent Dye, Lyophilized) does not include target-specific primers. Primers must be designed by the researcher or sourced separately to match the RNA target of interest. Multiple online tools are available for LAMP primer design, such as PrimerExplorer.

What equipment is needed to run the RT-LAMP reaction?

A thermal cycler is not required. You need a heat block, water bath, or any device capable of maintaining a stable isothermal temperature (typically 60–65 °C). For real-time fluorescence monitoring, a compatible isothermal fluorescence reader or qPCR instrument set to isothermal mode is needed. Endpoint results can also be assessed visually under UV light.

Can this kit be used with crude or minimally processed samples?

LAMP-based systems are generally more tolerant of common PCR inhibitors than conventional RT-PCR; however, sample quality and preparation can still significantly affect performance. The suitability of crude or minimally processed samples should be validated by the user for their specific sample type and application. Heavily inhibited samples may require a standard RNA extraction step.

How should the lyophilized kit be transported and stored?

The lyophilized format provides improved stability compared to liquid enzyme preparations, which can reduce cold-chain requirements during shipping. For specific storage temperature requirements and shelf-life information, refer to the product label and the Certificate of Analysis supplied with each lot. Contact Aladdin Scientific customer service if your shipment arrived outside recommended conditions.

Is this product suitable for diagnostic or clinical use?

No. This product is for research use only (RUO). It has not been approved, cleared, or licensed by any regulatory authority for use in diagnostic, clinical, or therapeutic applications. Researchers must comply with all applicable local regulations when using this product.

What could cause a false-positive signal in the no-template control?

False positives in the NTC are most commonly caused by aerosol contamination from previous amplification reactions, primer dimer formation, or non-specific primer interactions. To minimise this risk, use dedicated pre-amplification work areas and equipment, change gloves frequently, use aerosol-barrier tips, and optimise primer design. If primer dimer issues persist, adjusting primer concentrations or redesigning primers is recommended.

References

  1. Notomi T, et al. Loop-mediated isothermal amplification of DNA. Nucleic Acids Research. 2000;28(12):e63. (Foundational LAMP methodology reference) doi:10.1093/nar/28.12.e63
  2. Tomita N, et al. Loop-mediated isothermal amplification (LAMP) of gene sequences and simple visual detection of products. Nature Protocols. 2008;3(5):877-882. doi:10.1038/nprot.2008.57
  3. Aladdin Scientific. Product Documentation for RT-LAMP Isothermal Amplification Kit (with Fluorescent Dye, Lyophilized), SKU R1547530. Aladdin Scientific; [date on file].

Products are supplied for research and development use only. Not for use in humans, animals, diagnosis, or therapy.

目录: 常见问题(FAQs)

Da — 若无特别说明,分子量单位默认为道尔顿。   Mw — 重均分子量。   Mn — 数均分子量。

产品仅供科研与开发使用,不用于人体、动物、诊断或治疗。

引用本文

阿拉丁科学.《RT-LAMP Isothermal Amplification Kit (Lyophilized) FAQ》. 阿拉丁知识库,更新于 2026年10月26日。 https://www.aladdin-e.com/zh_cn/faqs/rt-lamp-isothermal-amplification-kit-fluorescent-dye-lyophilized-faq-en.html
这篇文章对您有帮助吗? Yes No 有 1 人觉得有帮助