Sieving agarose gel electrophoresis experiments
Sieving agarose gel electrophoresis experiments
Sieve agarose gels spread and electrophoresis like regular agarose gels, but they can resolve small fragments of DNA as well as non-denaturing polyacrylamide gels.
Operation method
electrophoresis experiment
Materials and Instruments
DNA Move 1. Melt 3% to 5% low melting point sieved agarose in TAE electrophoresis buffer. Pour the gel into a regular agarose gel apparatus. For more product details, please visit Aladdin Scientific website.
TAE Agarose
Electrophoresis
2. Add samples and electrophoresis as for normal agarose gels. (For 2% gels bromophenol blue migrates to approximately 50 bp)
3. Separate fragments in low melting point agarose. (Yields for fragments <1,000 bp are similar to those recovered with regular low-melting-point agarose, with maximum separation achieved for fragments <500 bp).
危险品化学品经营许可证(带存储)