已核实 DOI 相关产品: 10

Gallium ions induced in-situ MOF-derived hierarchical porous Co3O4 for ultra-high acetone response

Journal 2023 · IF 8.4 · 发表于 2023 年 10 月 27 日
作者: Rong Guo,Yongsheng Deng,Yinghao Jia,Caixin Shi,Wenpu Zhang,Ying Zhou,Xinghui Hou
阅读全文 在 PubMed 查看

摘要

In order to monitor the quality of the surrounding environment and realize the non-invasive screening of diabetes, it is necessary to develop a simple and sensitive acetone sensor. In this paper, GC x porous structures doped with different proportions of Ga element are prepared through calcining Co-MOF synthesized by solvothermal method . The findings indicate that the addition of Ga inhibits the further growth of grain and improves the uniformity of the adhered nanoparticles in GC x . Performance test shows that the GC4 sensor exhibit extremely ultra-high response (197.6, 50 ppm) acetone at 160 °C and relatively low detection limit of 0.1 ppm (2.3). The main reason for the significant improvement of GC x acetone sensitivity is that the introduction of Ga regulates the oxygen vacancy which provide rich reaction activation sites for the further reaction and diffusion of acetone and amplify resistance change by modulating the carrier concentration. A practical method for controlling oxygen vacancy and carrier concentration of sensing materials is shown in this work, which creates a new opportunity for the development of high-performance acetone sensors.

本研究中使用的阿拉丁产品

10 款产品在本文中被引用