已核实 DOI 相关产品: 22

Electrochemical Determination of Moxifloxacin Hydrochloride Based on Molecularly Imprinted Polymer Modified Carbon Paste Electrode

Journal 2023 · IF 1.5 · 发表于 2023 年 6 月 26 日
作者: Qing ZHOU,Ning Long,Lan LIU,Haiyun ZHAI,Mingfang ZHU
阅读全文 在 PubMed 查看

摘要

A highly selective molecularly imprinted polymer modified carbon paste electrode was developed. The Moxifloxacin Hydrochloride molecularly imprinted polymer was synthesized by thermal initiation precipitation polymerization, and the modified electrode was prepared by mixing graphite and polymer (90:10). Studied the electrochemical behavior and established the determination method of Moxifloxacin Hydrochloride at the electrode. The results showed that the sensor has high selectivity and sensitivity. and exhibited a linear voltammetric response for Moxifloxacin Hydrochloride in the concentration range of 3.13×10 -6 ~2.0×10 -4 mol•L -1 , with the limit of detection (LOD) of 5.9×10 -8 mol•L -1 (S/N=3). The sensor was applied to determine Moxifloxacin Hydrochloride in Avelox tablets and and human serum samples. The recoveries of Moxifloxacin Hydrochloride ranged from 97.2% to 104.5%.

本研究中使用的阿拉丁产品

22 款产品在本文中被引用