A relative humidity sensor based on open-cavity Fabry-Perot interferometer by fiber capillary splicing

Journal 2023 · IF 2.7 · 发表于 2023 年 3 月 1 日
作者: Xiao Lu,Huaping Gong,Ye Lu,Yiting Liu,Changyu Shen,Chunliu Zhao
阅读全文 在 PubMed 查看

摘要

A relative humidity (RH) sensor based on optical fiber Fabry-Perot interferometer (FPI) with open cavity is proposed and demonstrated, which is manufactured by cutting the fiber capillary (FC) with inclined end and splicing it with the flat end of another FC by overlapping method. Polyvinyl alcohol (PVA) film is coated on the flat end of one FC. The proposed sensor is tested under the conditions of 180 μm cavity length, 45 μm hole size and 15 μm film thickness. The results show that the sensitivity is about 0.70 nm/%RH within the range of 35 %RH ∼ 85 %RH. The proposed sensor has the merits of high sensitivity, fast response time, and high stability.

本研究中使用的阿拉丁产品

40 款产品在本文中被引用