已核实 DOI 相关产品: 6

Preparation of biotin-labeled graphene film for detecting nerve growth factor

Journal 2023 · IF 1.5 · 发表于 2023 年 2 月 2 日
作者: Bin Sun,Zhigang Wang,Bo Zhao,Yanfei Jin,Yaqiang Li,Song Yang
阅读全文 在 PubMed 查看

摘要

abstract In this study, an electrochemical immunosensor for nerve growth factor (NGF) detection was constructed based on graphene oxide (GO)-chitosan (CS) composite membrane. Scanning electron microscopy (SEM) was applied to characterize the morphology of GO-CS composite films. Cyclic voltammetry and differential pulse voltammetry were used to optimize the detection conditions of electrochemical immunosensors. The prepared electrochemical immunosensor has an excellent linear relationship with the peak electrode current when the concentration of NGF is 0.1–100 ng/mL with a limit of detection (0.0081 ng/mL). The recovery rate of serum samples was 99.00–104.06 %. Therefore, the immunosensor established by the institute is accurate, stable and sensitive.

本研究中使用的阿拉丁产品

6 款产品在本文中被引用