已核实 DOI PubMed 相关产品: 1

Application of LTA zeolite-modified electrode for sensitive detection of retinoic acid in tap water

Journal 2023 · IF 3.9 · 13(5): 3364-3370 · 发表于 2023 年 1 月 23 日
作者: Yuying Jiang,Yifeng E,Pengyan Wei,Jia Wang,Peng Chen,Lei Wang,Thomas F. Krenzel,Kun Qian,Xiyuan Tong
阅读全文 在 PubMed 查看

摘要

An electrochemical method based on a Linde Type-A zeolite-modified glass carbon electrode (LTA/GCE) was introduced for the determination of retinoic acid (RA). LTA zeolite could be synthesized through a hydrothermal method and served as a commercial electrochemical sensor with high stability and sensitivity in electrochemical progress. The as-synthesized product was characterized by scanning electron microscopy (SEM), differential thermal analysis (DTA), X-ray powder diffraction (XRD), and X-ray photoelectron spectroscopy (XPS). Under optimal conditions, a detection limit of 0.8 μM was obtained for RA with a linear range of 0.8–20.1 μM. This electrochemical method for determining RA was simpler and cheaper than previously reported methods. Furthermore, the modified electrode could be applied to the detection of RA in tap water, achieving a linear range of 1.4–15.0 μM with a detection limit of 1.4 μM and good recovery. The modified electrode designed by this method provided good selectivity, stability, and reproducibility for RA determination and reliable application for the analysis of RA in environmental water.

本研究中使用的阿拉丁产品

1 款产品在本文中被引用