已核实 DOI PubMed 相关产品: 14

Preparation of Lateral Flow PVDF Membrane via Combined Vapor- and Non-Solvent-Induced Phase Separation (V-NIPS)

Journal 2023 · IF 4.2 · 13(1): 91 · 发表于 2023 年 1 月 10 日
作者: Xiaoyun Wang,Dejian Chen,Ting He,Yue Zhou,Li Tian,Zhaohui Wang,Zhaoliang Cui
阅读全文 在 PubMed 查看

摘要

A large pore size Poly(vinylidene fluoride) (PVDF) membrane was prepared by the V-NIPS method using PVDF/N, N-dimethylacetamide (DMAc)/Polyvinyl pyrrolidone (PVP)/Polyethylene glycol (PEG) system. Firstly, the effect of different additive ratios on the membrane morphology and pore size was studied, and it was found that when the PVP:PEG ratio was 8:2, PVDF membranes with a relatively large pore size tend to be formed; the pore size is about 7.5 µm. Then, the effects of different exposure time on the membrane morphology and pore size were investigated, and it was found that as the vapor temperature increased, the pores on the surface of the membrane first became slightly smaller and then increased. Finally, the effects of different vapor temperatures on the membrane properties were discussed. The results showed that the as-prepared membrane exhibited suitable capillary flow rate and similar performance compared with a commercially available membrane in colloidal gold tests. The likely cause is that the amount of negative charge is less and the capillary migration rate is too fast. This paper provides a reference for the preparation of PVDF colloidal gold detection membrane.Keywords:Poly(vinylidene fluoride);vapor non-solvent-induced phase separation;detection of colloidal gold;capillary flow rate

本研究中使用的阿拉丁产品

14 款产品在本文中被引用